7
HP-210
PROCESS CONNECTION/END FITTING TYPE
MODEL
MF1/2X(
)-(
)-(
)-(
)-(
/
)-(MS)-( )-(
)
OPTION
(MS)
ALL MINI-FLOWMETERS ARE 1/2", 37 DEG. MALE FLARE PER MS33656
(1/4-TS)
1/4" TUBE STUB
(1/2-TS)
1/2" TUBE STUB
PRESSURE TAP @ ROTOR
MODEL
MF1/2X(
)-(
)-(
)-(
)-(
/
)-( )-(PT)-(
)
OPTION
(PT) 1/4"
PRESSURE TAP @ ROTOR
SPECIAL FEATURES
MODEL
MF1/2X(
)-(
)-(
)-(
)-(
/
)-( )-( )-(
E
)
OPTION
( E )
(6W )
HIGH PRESSURE UNITS, OVER 1000 PSIG TO MAX OF 6000 PSIG*
(6CW)
CRYOGENIC SERVICE RATED TO 6000 PSIG AND CLEANED FOR LOX
SERVICE.*
(CE)
CE MARK REQUIRED FOR EUROPE (PED-CE)
(PED-CE)
PED REQUIRES THAT BOTH THE OPERATING PRESSURE AND
TEMPERATURE MUST BE KNOWN AND ENTERED ON THE ORDER.
THIS INFORMATION WILL BE MARKED ON THE HOUSING TO MEET PED
REQUIREMENTS.
(SEP-CE)
SOUND ENGINEERING PRACTICE
(SP)
ANY SPECIAL FEATURES THAT ARE NOT COVERED IN THE MODEL
NUMBER, USE A WRITTEN DESCRIPTION OF THE -SP.
*WELDED CAP-MINI MUST BE RETURNED TO THE FACTORY FOR
REPAIR –
NOT FIELD REPAIRABLE.
1.2 Specification
Linearity:
1.0% of reading over 10:1 flow range
Repeatability:
0.25% of reading
Flow Ranges:
Liquid Applications:
0.02 to 3.5 GPM
w/ MAG pickup in 10:1 turndown
0.007 to 3.5 GPM
w/ MCP pickup in 25:1 turndown
Gas Applications:
0.005 to 1 ACFM
w/ MCP pickup;
turndown
dependent on gas density
Temperature Range:
-450 °F to +450 °F
Output:
Dependent on pickup coil selected