Hobo U14 User Manual Download Page 2

HOBO U14 Data Logger User Manual 

2

 

Plot

 

A:

 

Internal

 

Temperature

 

Sensor

 

Accuracy

 

and

 

Resolution

 

Specifications

 

 

LCD

 

Size

 

33

 

x

 

50.8

 

mm

 

(1.3

 

x

 

2

 

inches)

 

Elements

 

 

Temperature

 

and

 

relative

 

humidity

 

simultaneously

 

 

°C

 

or

 

°F

 

(selectable

 

within

 

host

 

software)

 

 

Memory

 

remaining

 

and

 

battery

 

level

 

 

Flashing

 

ALERT

 

for

 

out

of

limits

 

conditions

 

(selectable

 

within

 

host

 

software),

 

which

 

stops

 

flashing

 

on

 

offload

 

or

 

return

 

to

 

normal

 

range

 

Alarms

 

Set

 

points

 

High

 

and

 

low

 

set

 

points

 

for

 

both

 

temperature

 

and

 

relative

 

humidity

 

with

 

selectable

 

delays

 

Reset

 

options

 

Alert

 

conditions

 

reset

 

on

 

offload

 

or

 

return

 

to

 

normal

 

range

 

Selectable

 

Contact

 

Relay

 

Normally

 

Closed

 

or

 

Normally

 

Open

 

Contact

 

rating

 

48VDC,

 

1A

 

max

 

Contact

 

resistance

 

Less

 

than

 

1

 

Ohm

 

Range

 

0%

 

Low

 

Battery

 

Range

 

Communications

 

Method

 

Offloads

 

data

 

to

 

PC

 

or

 

U

Shuttle

 

via

 

USB

 

cable

 

Speed

 

Readout

 

full

 

logger

 

(64K)

 

in

 

less

 

than

 

30

 

seconds

 

Time

 

accuracy

 

±1

 

minute

 

per

 

month

 

at

 

+20°C

 

(+68°F)

 

Power

 

3

 

AAA

 

Alkaline

 

batteries,

 

user

replaceable

 

Dimensions

 

125

 

x

 

92

 

x

 

31

 

mm

 

(4.9

 

x

 

3.6

 

x

 

1.2

 

in)

 

Weight

 

170

 

g

 

(6.0

 

oz)

 

with

 

batteries

 

Internal

 

12

Bit

 

Temperature

 

Sensor

 

Measurement

 

range

 

20°C

 

to

 

+50°C

 

(

4°F

 

to

 

+122°F)

 

Accuracy

 

±0.21°C

 

from

 

 

to

 

50°C

 

(±0.38°F

 

from

 

32°

 

to

 

122°F);

 

±0.13°C

 

(0.24°F)

 

typical

 

(see

 

Plot

 

A)

 

Resolution

 

0.02°C

 

@

 

25°C

 

(0.04°F

 

@

 

77°F)

 

(see

 

Plot

 

A)

 

Response

 

time

 

15

 

minutes

 

(to

 

90%

 

in

 

airflow

 

of

 

1

 

m/sec)

 

Temperature

 

Accuracy

 

Drift

 

Negligible

 

Internal

 

12

Bit

 

Relative

 

Humidity

 

Sensor

 

(User

 

replaceable)

 

Measurement

 

range

 

0

100%

 

RH,

 ‐

20

 

to

 

50°C

 

(

4

 

to

 

122°F)

 

Accuracy

 

+/

‐ 

2.5%

 

from

 

10%

 

to

 

90%

 

RH

 

(typical),

 

to

 

a

 

maximum

 

of

 

+/

‐ 

3.5%

 

including

 

hysteresis

 

(see

 

Plot

 

B)

 

Resolution

 

0.03%

 

RH

 

@

 

25°C

 

(77°F)

 

Response

 

time

 

2

 

minutes

 

(to

 

90%

 

in

 

airflow

 

of

 

1

 

m/sec)

 

Accuracy

 

Drift

 

<2%

 

over

 

5

 

years

 

typical

 

Hysteresis

 

1%

 

Typical

 

External

 

Sensors

 

For

 

External

 

Sensor

 

Specifications,

 

see

 

the

 

sensor’s

 

user

 

manual

 

Battery

 

Life

 

The

 

batteries

 

will

 

last

 

one

 

year

 

in

 

typical

 

conditions

 

(logging

 

intervals

 

of

 ≥ 

1

 

minute

 

with

 

weekly

 

offloads

 

and

 

average

 

temperatures

 

greater

 

than

 

10°C

 

or

 

+50°F).

 

Frequent

 

offloads

 

and/or

 

extreme

 

temperatures

 

will

 

reduce

 

battery

 

life.

 

At

 

temperatures

 

below

 

freezing

 

(0°C

 

or

 

+32°F),

 

batteries

 

will

 

typically

 

require

 

replacement

 

every

 

six

 

months.

 

In

 

these

 

conditions

 

the

 

battery

 

level

 

bar

 

graph

 

should

 

be

 

checked

 

regularly.

 

See

 

Battery

 

Level

 

Indicators

 

on

 

page

 

8.

 

 

The

 

CE

 

Marking

 

identifies

 

this

 

product

 

as

 

complying

 

with

 

all

 

relevant

 

directives

 

in

 

the

 

European

 

Union

 

(EU).

 

Temperature

 

Accuracy

 

and

 

Resolution

 

The

 

maximum

 

reading

 

error

 

for

 

the

 

internal

 

temperature

 

sensors

 

is

 

shown

 

at

 

right.

 

This

 

is

 

a

 

worst

 

case

 

error.

 

In

 

a

 

typical

 

logger,

 

temperature

 

errors

 

will

 

be

 

substantially

 

lower.

 

NIST

 

certification

 

of

 

temperature

 

accuracy

 

for

 

some

 

sensors

 

is

 

available

 

from

 

Onset.

 

The

 

temperature

 

resolution

 

for

 

internal

 

sensors

 

is

 

also

 

shown

 

at

 

right.

 

Resolution

 

is

 

the

 

smallest

 

difference

 

between

 

adjacent

 

temperature

 

steps

 

that

 

the

 

logger

 

can

 

report.

 

The

 

logger

 

will

 

typically

 

experience

 

little

 

or

 

no

 

accuracy

 

drift

 

unless

 

the

 

electronic

 

components

 

or

 

temperature

 

sensor

 

are

 

damaged

 

mechanically

 

or

 

by

 

exposure

 

to

 

environmental

 

factors

 

beyond

 

the

 

specifications,

 

such

 

as

 

high

 

heat

 

and

 

humidity.

 

Summary of Contents for U14

Page 1: ...es in typical conditions Built in relay for use with Remote Alarm or Automatic Dialer Direct USB interface for launching and data readout using HOBOware Sample logging interval can be set from one sec...

Page 2: ...e 0 100 RH 20 to 50 C 4 to 122 F Accuracy 2 5 from 10 to 90 RH typical to a maximum of 3 5 including hysteresis see Plot B Resolution 0 03 RH 25 C 77 F Response time 2 minutes to 90 in airflow of 1 m...

Page 3: ...1 may require replacement if it is damaged mechanically or by exposure to condensation or chemicals The replacement sensor part number HUM RHPCB 3 or RHPCB 3A is available from Onset or an Onset Autho...

Page 4: ...f the case c Feed the wires through the holes in the relay terminal d Tighten the screws on the terminal e Replace the battery compartment cover f Connect the wires to the Remote Alarm or Automatic Di...

Page 5: ...as never been connected to the computer before it may take a few seconds for the new hardware to be detected Windows only 5 Start HOBOware and open the Launch window From the Device menu select Launch...

Page 6: ...ted when the Host has relaunched the logger or when the sensor reading has returned within limits e Set Relay Contact If you are using an external device that will be triggered by an alarm such as a R...

Page 7: ...re software on the computer 5 Optional If you have more than one logger connected to the computer connect to the HOBO U14 by selecting Device Select and then select the HOBO U14 from the Select Device...

Page 8: ...segments decreases as remaining memory decreases NOTE If the memory is full the logger will no longer log The logger will continue to monitor conditions however and will trigger an alert if the readin...

Page 9: ...will record values of 888 88 C 888 88 F for temperature and 0 RH No External Sensor If the U14 002 logger is launched and no external sensor has been connected the display will show dashes and will l...

Page 10: ...t is damaged mechanically or by exposure to condensation or chemicals The replacement sensor Part No HUM RHPCB 3A is available from Onset or an Onset Authorized Dealer for U14 001 loggers with serial...

Reviews: