09-
9.4 Hot-air heating with integrated boiler
(only in 460 LU Excellent)
Heating while driving is forbidden.
The Combi 4 LPG heating is a hot-air heating
system with an integrated hot-water boiler (con
-
tents: 10 l).
It is possible to operate the heating system both
with and without water.
Location
• In the left single bed behind the washroom.
Initial operation
• Set the air exit nozzle in the camper so that
the hot air exits where you want it to.
• Check that the flue is unobstructed. Any co-
vers must always be removed.
• Open the gas bottle and the gas shutoff spi-
gots.
Operating device
a) knob for room temperature (1-5)
b) green LED shines: “in operation”
green LED blinks:
“return water” has been activated to reduce
the temperature of the device
c) operating in summer
(water temperature 40° C or 60° C)
d) operating in winter
(heating
without
controlled water temperature
or with empty water system)
e) operating in winter
(heating
with
controlled water temperature)
f) knob is “Off”
g) yellow LED shines: “boiler is in warm-up pha
-
se”
h) red LED shines, red LED blinks:
“Malfunction” - take XXXXX and carefully cle
-
an fan wheel with a brush.