07-
7.3 Electrical supply
Supply via mains connection
The camper receives its electric power supply
via the
30 V CEE feeder plug on the side wall of
the vehicle.
To set up an electric connection
• Pull out the
3-pole plug that connects to the
base vehicle.
• Switch off the automatic circuit breaker
m
by
pressing the rocker button down
n
.
• T
ake hold of the bottom of the cover flap of
the external socket
j
and pull it up.
• Completely unwind the connector cable, at-
tach the plug
k
and click it into place.
• Switch the automatic circuit breaker
m
back
on.
To disconnect the electric connection
• Switch off the automatic circuit breaker
m
by
pressing the rocker button down
n
.
• Press the lever
l
in the external socket
down.
• Remove the CEE plug
k
.
• Pr
ess the cover flap
j
down until it clicks
into place.
The
30 V system is protected by a two-pole
3
A automatic circuit breaker
m
, which is loca-
ted in the clothes cupboard. (Exceptions to this
include special installations, such as ultraheat,
hot-water heating, etc.. In this case, an additio-
nal two-pole
6 A circuit breaker has been instal-
led.) If there are two automatic circuit breakers,
both must be switched on.
Electricity for the camper can be obtained from
the following connections:
-
30 V mains connection 50 Hz
- via the base vehicle if it is connected using
the 13-pole plug (limited functions)
- via a built-in auxiliary battery (special request)
Everything that uses
V, such as lighting,
water supply, etc., is available.
3
5
The external
30 V supply must be
protected by a residual current device
(RCD).