10-
•
If the flame extinguishes again, r
e-ignition
takes place during the closing phase of the
fusible cut-out of the ignition safety switch
(approx. 30 seconds).
•
If no flame is ignited, the automatic ignitor
k
will continue to work until the operation
handle
j
is switched to “0”.
1
Changing batteries on the automatic
ignitor
k
If you cannot hear any ignition sparks or only
hear them in intervals of more than one second,
then you must insert a new battery.
• Ensure that the heating has been switched
off.
• Remove the radiator cover (see Truma opera-
ting instructions).
• Push the cover of the battery compartment
up and exchange the battery (take special
note of plus and minus).
• Close the battery compartment.
• Use only a temperature-resistant (+70° C) and
leakproof mignon battery.
During initial operation of the heating
system, there will be a slight nui-
sance caused by smoke and odours.
Immediately turn the operating
handle on the heating
j
to position
„10“ and set the circulation fan to the
highest position. Open all doors and
windows and air the camper well.
The smoke and odours will disperse
after a short while.
To shut off
•
Turn the operation handle
j
to position "0".
The automatic ignitor is thereby shut off.
•
If necessary, let the circulation fan continue to
run for a while.
•
Close the bottle valve and the quick-close
valve if the unit is not used for a longer period
of time.
Insert new batteries before the begin-
ning of each heating season.
Also note the separate operating
instructions from the manufacturer.