TM-258 267 Page 7
Handler 140
4-4. Process/Polarity Table
Process
Polarity
Cable Connections
Cable To Gun
Cable To Work
GMAW
−
Solid wire with shielding
gas
DCEP
−
Reverse polarity
Connect to positive (+) output
terminal
Connect to negative (
−
) output ter-
minal
FCAW
−
Self-shielding wire
−
no
shielding gas
DCEN
−
Straight Polarity
Connect to negative (
−
) output
terminal
Connect to positive (+) output termi-
nal
4-5. Changing Polarity
1
Lead Connections For Direct
Current Electrode Negative
(DCEN)
2
Lead Connections For Direct
Current Electrode Positive
(DCEP)
Always read and follow wire
manufacturer’s recommended
polarity, and see Section 4-4.