4-7. Connecting Input Power
!
Installation must meet all National
and Local Codes
−
have only
qualified persons make this
installation.
!
Special installation may be
required where gasoline or volatile
liquids are present
−
see NEC
Article 511 or CEC Section 20.
A 115 volts AC, 20 ampere individual circuit
protected by time-delay fuses or circuit
breaker is required.
1
Plug From Unit
2
Receptacle
−
NEMA Type 5
−
15R
(Customer Supplied)
2
Input6 2011
−
03 258 641-A
!
Do not move or operate unit
where it could tip.
1
4-8.
Selecting Extension Cord (Use Shortest Cord Possible)
Single Phase AC
Input Voltage
Conductor Size
−
AWG (mm
2
)*
10 (5.3)
12 (3.3)
Maximum Allowable Cord Length in ft (m)
115
100 (30.5)
50 (15.0)
*Conductor size is based on maximum 3% voltage drop