OM-945 Page 25
8-4.
Overload Protection (Onan-Powered Units)
802 342 / Ref. 802 353-B
Stop engine. Disconnect
negative (–) battery cable.
If the unit is extremely over-
loaded, weld and generator
power will stop. Turn unit off
and restart to reset the genera-
tor protection circuit and re-
store weld and generator pow-
er output.
If the rated output of the unit is
exceeded, engine speed may
vary rapidly until the weld or
generator power load is re-
duced.
1
Fuse F1 (See Parts List)
F1 protects the generator excitation
circuit. If F1 opens, there is no/low
weld and generator power output.
2
Fuse F6 (See Parts List)
F6 protects the engine wiring sys-
tem. If F6 opens, the engine does
not crank. If F6 opens while the en-
gine is running, the engine stops.
Replace any open fuses. Reinstall
cover before operating.
If a fuse opens, it usually indi-
cates a more serious problem
exists. Contact a Factory Au-
thorized Service Agent.
3/8 in
1
2
Tools Needed:
8-5.
Servicing Optional Spark Arrestor (Onan-Powered Units)
Ref. 801 682-A / Ref. 802 353-A
Stop engine and let cool.
1
Spark Arrestor Screen
Clean and inspect screen. Replace
spark arrestor if screen wires are
broken or missing.
1/4 in
1
Tools Needed: