OM-945 Page 23
8-2.
Routine Maintenance (Onan-Powered Units)
Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.
Note
Recycle
engine
fluids.
Stop engine before maintaining.
See also Engine Manual and maintenance label.
Service engine more often if used in severe condi-
tions.
*
To be done by Factory Authorized Service Agent.
Every 8 h
Wipe up spills.
Check fluid levels.
See Section 5-2.
20 h
25 h
Check and clean
spark arrestor screen.
See Section 8-5.
Service air
cleaner wrapper
(foam element).
See Section 8-3.
Every 50 h
Clean and
tighten weld
terminals.
Every 100 h
Clean cooling system.
See Engine Manual.
Change oil. See
Section 8-6 and
maintenance label.
Clean and
tighten battery
connections.
Service air
cleaner element.
See Section 8-3.
Every 200 h
Replace fuel
filter. See
Section 8-6.
Change oil filter. See
Section 8-6 and
maintenance label.
Check
spark
plugs.
Replace
unreadable
labels.