2. Preparation for Storage
When a generator set is to be stored or removed from operation, special precautions should be taken to
protect the internal and external parts from rust, corrosion, and gumming in the engine fuel system.
A. General
(1) The unit should be prepared for storage as soon as possible after being removed from service.
(2) The unit should be stored in a building which is dry and which may be heated during winter
months.
(3) Moisture absorbing chemicals are available for use where excessive dampness is a problem, how-
ever the unit must be completely packaged and sealed if moisture absorbing chemicals are to be ef-
fective.
B. Temporary Storage
When storing the unit for 30 days or less, prepare as follows:
(1) Lubricate the unit completely in accordance with instructions in Sect. 2-1. This will include chang-
ing engine oil, and all filter elements.
(2) Start the engine and operate for about two minutes so that all internal engine components will be
coated with new oil.
NOTE: Do not drain the fuel system or crankcase after this run.
(3) Make certain the cooling system antifreeze solution is adequate to protect below the lowest tem-
peratures expected during the storage period. See 2-1; Para. 6, D. Be sure the solution is thoroughly
mixed.
(4) Clean the exterior of the engine with fuel oil. Dry with clean rags and compressed air.
(5) Seal all engine openings. Use a waterproof, vaporproof material which is strong enough to resist
puncture damage from air pressures.
C. Long Time Storage (Over 30 Days)
(1) The unit may be stored for long periods with no special preparation if it is possible to operate the
engine once each week.
(a) Make certain the cooling system is adequately protected.
(b) Start the engine and operate at a fast idle
(800 to 1000 RPM)
until coolant temperature has
reached at least 140 deg F.
WARNING: MAKE CERTAIN OF ADEQUATE VENTILATION BEFORE START-
ING THE ENGINE.
(c) Operate normal operating controls.
(2) If weekly operation is not possible, prepare and protect the engine in accordance with instructions
in John Deere Operator’s Manual.
(3) To protect the generator and other electrical components, the complete unit should be packaged,
using moisture proof packaging and sealing material. Place containers of moisture absorbing chemi-
cals, such as silica-gel, in the unit before packaging.
OM-2029
September 30/89 Revised
1-2
Page 3
Summary of Contents for 140GT17K
Page 2: ...This page intentionally left blank ...
Page 16: ...This page intentionally left blank OM 2029 Addendum June 6 90 Page 4 ...
Page 17: ......
Page 18: ......
Page 42: ...Output Terminal Panel Figure 11 OM 2029 1 1 September 30 89 Revised Page 24 ...
Page 46: ...This page intentionally left blank OM 2029 1 2 September 30 89 Revised Page 4 ...
Page 74: ...This page intentionally left blank OM 2029 2 2 September 30 89 Revised Page 6 ...
Page 122: ...Generator Set Figure 1 OM 2029 4 3 September 30 89 Revised Page 2 ...
Page 126: ...This page intentionally left blank 4 3 July 27 90 Page 3C OM 2029 ...
Page 128: ...Canopy Assembly Figure 2 OM 2029 4 3 September 30 89 Revised Page 4 ...
Page 130: ...Generator Set Without Canopy Figure 3 OM 2029 4 3 September 30 89 Revised Page 6 ...
Page 132: ...This page intentionally left blank OM 2029 4 3 September 30 89 Revised Page 8 ...
Page 134: ...Radiator and Cooling System Group Figure 4 OM 2029 4 3 September 30 89 Revised Page 10 ...
Page 136: ...Air Cleaner Assembly Figure 5 OM 2029 4 3 September 30 89 Revised Page 12 ...
Page 138: ...Electric Governor Kit Figure 6 OM 2029 4 3 September 30 89 Revised Page 14 ...
Page 140: ...Panel Engine Control Assembly Figure 7 OM 2029 4 3 September 30 89 Revised Page 16 ...
Page 142: ...Generator Control Box Assembly Figure 8 4 3 July 27 90 Page 18 OM 2029 ...
Page 144: ...This page intentionally left blank OM 2029 4 3 September 30 89 Revised Page 20 ...
Page 146: ...Stator Terminal Panel Assembly Figure 9 OM 2029 4 3 September 30 89 Revised Page 22 ...
Page 148: ...Power Module Panel Assembly Figure 10 OM 2029 4 3 September 30 89 Revised Page 24 ...
Page 150: ...Generator Group Figure 11 OM 2029 4 3 September 30 89 Revised Page 26 ...
Page 152: ...Fuel Line Assembly Figure 12 OM 2029 4 3 September 30 89 Revised Page 28 ...
Page 156: ...This page intentionally left blank 4 3 March 16 90 Page 32 OM 2029 ...
Page 158: ...This page intentionally left blank 4 3 March 16 90 Page 34 OM 2029 ...
Page 160: ...Brake Kit Assembly Figure 14 4 3 March 16 90 Page OM 2029 ...
Page 162: ...This page intentionally left blank 4 3 March 16 90 Page 38 OM 2029 ...
Page 168: ...This page intentionally left blank 4 3 July 27 90 Page 44 OM 2029 ...
Page 178: ...This page intentionally left blank OM 2029 4 4 September 30 89 Revised Page 10 ...
Page 180: ...This page intentionally left blank OM 2029 5 0 September 30 89 Revised Page 2 ...
Page 182: ...This page intentionally left blank OM 2029 6 0 September 30 89 Revised Page 2 ...
Page 184: ...This page intentionally left blank OM 2029 Unusual Service Conditions September 30 89 Page 2 ...
Page 185: ......
Page 186: ......