OM-926 Page 15
4-10. Wiring Optional 240 Volt Plug (119 172) For Connection To Bobcat, Trailblazer Or
Champion 10,000
Ref. 120 813-D / Ref. 803 222
1
Input And Grounding
Conductors
2
Plug Wired for 240 V, 2-Wire
Load
3
Neutral (Brass) Terminal And
Prong
(Not Used)
4
Load 1 (Brass)Terminal And
Prong
5
Load 2 (Brass) Terminal And
Prong
6
Ground (Brass) Terminal And
Prong
7
Black And White Input
Conductors
8
Green Or Green/Yellow
Ground Conductor
Y
Always connect green or
green/yellow wire to ground
terminal, never to a load
terminal. Connect black (L1)
and white (L2) wires to load
terminals.
Tools Needed:
7
Green Or
Green/Yellow
2
3
4
5
6
240V
8
3/16 in
8
7
6
5
4
3
Plug Front
View
Y
Engine Control Switch must be set at “RUN”
position
−
not “RUN/IDLE”.
Y
Set generator Fine Adjustment Control to 10
for maximum auxiliary power, if applicable.
1
Summary of Contents for AirForce 625
Page 4: ......
Page 31: ...OM 926 Page 27 SECTION 7 ELECTRICAL DIAGRAM 212 926 A Figure 7 1 Circuit Diagram ...
Page 37: ...Notes ...
Page 38: ...Notes ...