OM-227 978 Page 31
9-2.
Typical MIG Process Control Settings
These settings are guidelines only. Material and wire type, joint design, fitup,
position, shielding gas, etc. affect settings. Test welds to be sure they comply to
specifications.
NOTE
3.5 x 125 A = 437 ipm
2 x 125 A = 250 ipm
1.6 x 125 A = 200 ipm
30
−
90 A
40
−
145 A
50
−
180 A
Convert Material
Thickness to
Amperage (A)
Material thickness determines weld
parameters.
.035 in
Recommendation
Wire Speed
(Approx.)
1/8 or 0.125 in
(0.001 in = 1 ampere)
0.125 in = 125 A
Wire Size
Amperage Range
0.023 in
0.030 in
0.035 in
Select Wire Size
Wire
Size
0.023 in
0.030 in
0.035 in
3.5 in per ampere
2 in per ampere
1.6 in per ampere
Select Wire Speed
(Amperage)
125 A based on 1/8 in
material thickness
ipm = inches per minute
Low voltage: wire stubs into work
High voltage: arc is unstable (spatter)
Set voltage midway between high/low voltage
Select Voltage
Ref. 804 685-A
Voltage controls height
and width of weld bead.
Wire speed (amperage) controls weld
penetration (wire speed = burn-off rate)
Summary of Contents for Handler 210
Page 24: ...OM 227 978 Page 20 6 2 Weld Parameter Chart For 230 VAC Model ...
Page 25: ...OM 227 978 Page 21 227 949 A ...
Page 31: ...OM 227 978 Page 27 Notes ...
Page 32: ...OM 227 978 Page 28 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram ...
Page 33: ...OM 227 978 Page 29 227 951 A ...
Page 43: ...OM 227 978 Page 39 Notes ...
Page 49: ...Notes ...