OM-227 978 Page 13
5-5. Installing Gas Supply
Obtain gas cylinder and chain to
running gear, wall, or other
stationary support so cylinder
cannot fall and break off valve.
1
Cap
2
Cylinder Valve
Remove cap, stand to side of valve,
and open valve slightly. Gas flow
blows dust and dirt from valve.
Close valve.
3
Cylinder
4
Regulator/Flowmeter
Install so face is vertical.
5
Regulator/Flowmeter Gas
Hose Connection
6
Welding Power Source Gas
Hose Connection
Connect supplied gas hose
between regulator/flowmeter gas
hose connection, and fitting on rear
of welding power source.
7
Flow Adjust
Flow rate should be set when gas is
flowing through welding power
source and welding gun. Open
pressure assembly so that wire will
not feed. Press gun trigger to start
gas flow.
Typical flow rate is 20 cfh (cubic
feet per hour). Check wire
manufacturer’s recommended
flow rate.
After flow is set, close pressure
assembly.
Tools Needed:
Ref. 804 654-A / 802 441 / Ref. 804 688-A
5/8, 1-1/8 in
.
DO NOT use Argon/Mixed gas regulator/flowmeter
with CO
2
shielding gas. See Parts List for optional
CO
2
gas regulator/flowmeter.
Pressure Assembly
Open
Pressure Assembly
Closed
6
Argon Gas Or
Mixed Gas
1
2
3
4
5
7
Summary of Contents for Handler 210
Page 24: ...OM 227 978 Page 20 6 2 Weld Parameter Chart For 230 VAC Model ...
Page 25: ...OM 227 978 Page 21 227 949 A ...
Page 31: ...OM 227 978 Page 27 Notes ...
Page 32: ...OM 227 978 Page 28 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram ...
Page 33: ...OM 227 978 Page 29 227 951 A ...
Page 43: ...OM 227 978 Page 39 Notes ...
Page 49: ...Notes ...