Intesis
TM
INMBSPAN001A000
User’s Manual r1.
3 EN
© HMS Industrial Networks S.L.U. - All rights reserved
This information is subject to change without notice
URL https://www.intesis.com
10 / 22
Register Address
(protocol address)
Register Address
(PLC address)
R/W Description
14
15
R
Water outlet/room/pool
▪
-127..127ºC (ºC/x10ºC)
▪
-260.6..260.6ºF
15
16
R
Water outlet/room/pool
▪
-127..127ºC (ºC/x10ºC)
▪
-260.6..260.6ºF
16
17
R
Zone 1 temperature setting mode
▪
1: Room temperature
▪
2: Compensation curve (Water Temp)
▪
3: Direct (Water Temp)
▪
4: Pool Temp
17
18
R
Zone 2 temperature setting mode
▪
1: Room temperature
▪
2: Compensation curve (Water Temp)
▪
3: Direct (Water Temp)
▪
4: Pool Temp
18
19
R
Zone 1 min Setpoint temperature
▪
Any (ºC/x10ºC)
19
20
R
Zone 1 max Setpoint temperature
▪
Any (ºC/x10ºC)
20
21
R
Zone 2 min Setpoint temperature
▪
Any (ºC/x10ºC)
21
22
R
Zone 2 max Setpoint temperature
▪
Any (ºC/x10ºC)
4.2.3
Tank Configuration
Register Address
(protocol address)
Register Address
(PLC address)
R/W Description
30
31
R/W
▪
0: Off
▪
1: On
32
33
R
Tank current water temperature
▪
-127..127ºC (ºC/x10ºC)
▪
-260.6..260.6ºF
33
34
R/W
Tank water setpoint temperature
▪
40..66/75ºC (ºC/x10ºC)
▪
104..150.8/167ºF
34
35
R
▪
1: Internal
▪
2: External
35
36
R
Tank min water setpoint temperature
▪
Any (ºC/x10ºC/Fº)
36
37
R
Tank max water setpoint temperature
▪
Any (ºC/x10ºC/Fº)