HMS Intesis IBMBSKNX1000000 User Manual Download Page 2

Intesis

TM

 Modbus Server - KNX

 

 

      

 

 

     

User Manual r1.2 eng

 

 

  

 

 

 

 

 

© HMS Industrial Networks S.L.U - All rights reserved

 

This information is subject to change without notice

 

 

  URL 

  

 http

s

://www.intesis.com  

 
 

                2 / 18

 

 
 
 
 
 
 
 
 
 
 
 

Important User Information 

Disclaimer 

The information in this document is for informational purposes only. Please inform HMS Industrial Networks of any 
inaccuracies or omissions found in this document. HMS Industrial Networks disclaims any responsibility or liability for 
any errors that may appear in this document. 

HMS  Industrial  Networks  reserves  the  right  to  modify  its  products  in  line  with  its  policy  of  continuous  product 
development. The information in this document shall therefore not be construed as a commitment on the part of 
HMS Industrial Networks and is subject to change without notice. HMS Industrial Networks makes no commitment 
to update or keep current the information in this document. 

The  data,  examples  and  illustrations  found  in  this  document  are  included  for  illustrative  purposes  and  are  only 
intended to help improve understanding of the functionality and handling of the product. In view of the wide range 
of possible applications of the product, and because of the many variables and requirements associated with any 
particular implementation, HMS Industrial Networks cannot assume responsibility or liability for actual use based on 
the data, examples or illustrations included in this document nor for any damages incurred during installation of the 
product. Those responsible for the use of the product must acquire sufficient knowledge in order to ensure that the 
product  is  used  correctly  in  their  specific  application  and  that  the  application  meets  all  performance  and  safety 
requirements including any applicable laws, regulations, codes and standards. Further, HMS Industrial Networks will 
under no circumstances assume liability or responsibility for any problems that may arise as a result from the use of 
undocumented features or functional side effects found outside the documented scope of the product. The effects 
caused by any direct or indirect use of such aspects of the product are undefined and may include e.g. compatibility 
issues and stability issues. 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Intesis IBMBSKNX1000000

Page 1: ...KNX USER MANUAL Issue date 05 2018 r1 2 ENGLISH...

Page 2: ...nd are only intended to help improve understanding of the functionality and handling of the product In view of the wide range of possible applications of the product and because of the many variables...

Page 3: ...URL https www intesis com 3 18 Gateway for the integration of KNX TP 1 EIB installations into Modbus RTU and or Modbus TCP enabled monitoring and control systems ORDER CODE LEGACY ORDER CODE INMBSKNX...

Page 4: ...s RTU 8 Modbus TCP 8 Address Map 8 Points definition 9 4 Connections 10 Powering the device 11 Connection to KNX 11 Connection to Modbus 11 4 3 1 Modbus TCP 11 4 3 2 Modbus RTU 11 Connection to the co...

Page 5: ...own KNX TP 1 EIB system and vice versa For this Intesis acts as a Modbus TCP server or Modbus RTU slave device in its Modbus interface allowing read write points from the Modbus client device s and o...

Page 6: ...X group address With this all the Modbus system is seen as one more KNX device from the KNX system point of view with the same configuration and operation characteristics When a change in any Modbus p...

Page 7: ...al point into Intesis is determined by the flags configured for the point See details in section 2 2 Points definition Every internal datapoint to define has the following KNX properties Property Desc...

Page 8: ...te Modbus registers Modbus functions 06 and 16 Single Multiple Holding Registers and Write Multiple Holding Registers can be used to write Modbus registers If poll records are used to read or write mo...

Page 9: ...ment C2 16 32 bits Float 16 bits Bitfields Error comm Function code One of the following Modbus function codes can be used 1 Read Coils 2 Read Discrete Inputs 3 Read Holding Registers 4 Read Input Reg...

Page 10: ...abled default IP is 192 168 100 246 PortA KNX Connect the KNX TP1 bus to connectors A3 and A4 of gateway s PortA Respect the polarity PortB Modbus RTU Connect the EIA485 bus to connectors B1 B B2 A an...

Page 11: ...1 network to the KNX port of Intesis The cable to be used shall be a straight Ethernet UTP FTP CAT5 cable 4 3 2 Modbus RTU Connect the communication cable coming from the Modbus network to the port m...

Page 12: ...tegration are Intesis gateway Link to download the configuration tool Product documentation Intesis MAPS Configuration monitoring tool for Intesis KNX series 5 2 1 Introduction Intesis MAPS is a Windo...

Page 13: ...ubsets of information are shown in this window General Gateway general parameters KNX KNX interface configuration and Modbus Client Modbus interface parameters Figure 5 2 Intesis MAPS configuration ta...

Page 14: ...mmunication Console window Intesis will reboot automatically once the new configuration is loaded Figure 5 4 Intesis MAPS Receive Send tab After any configuration change do not forget to send the conf...

Page 15: ...HMS Industrial Networks S L U All rights reserved This information is subject to change without notice URL https www intesis com 15 18 Figure 5 5 Diagnostic More information about the Diagnostic secti...

Page 16: ...ply voltage applied WARNING In order to avoid earth loops that can damage Intesis and or any other equipment connected to it we strongly recommend The use of DC power supplies floating or with the neg...

Page 17: ...24VDC Push Button Button A Check the user manual Button B Check the user manual Operation Temperature 0 C to 60 C Ethernet 1 x Ethernet 10 100 Mbps RJ45 2 x Ethernet LED port link and activity Operat...

Page 18: ...reserved This information is subject to change without notice URL https www intesis com 18 18 7 Dimensions Recommended available space for its installation into a cabinet wall or DIN rail mounting wit...

Reviews: