User Guide | FreeSpeak Edge Base Station
Device Type
Port Function
Supports call signalling?
HelixNet HLI-4W2
4-wire
Yes
MVX-A16 (Eclipse Matrix)
4-wire-X
Yes
(Identified as a CCI-22 in the
software)
Other matrices (third party)
Depends on third-party
pinout
No
HME DX210/DX410
4-wire
Yes
FreeSpeak/FreeSpeak II Base II
4-wire
Yes**
Edge/Arcadia Station
When connecting two
Stations with a straight
cable, the
Port
Function
settings must
be as follows:
Station 1:
4-wire
Station 2:
4-wire-X
Yes
2-way radio : 4-wire device with
relay activation
*
Depends on third-party
pinout
Yes (call signal can fire relay)
*
Connect to a DB9 on the Station rear.
**
On a FreeSpeak II Base Station only ports 3 and 4 support call signalling.