Page 1: ...HJM_ESD C_ENG_Rev 3_09 02 2018 Made in Spain 1 22 ORIGINAL OPERATING INSTRUCTIONS Read carefully and retain for future reference CERAMIC HEATER Type ESD C Models ESD C750 ESD C1000 ESD C1500 ESD C2000...

Page 2: ...tage is the 230 Volts and correspond to the marked on the nameplate of the appliance 4 Check that the power is sufficient to supply the appliances The total draw of the radiators currents must not exc...

Page 3: ...m the bath shower or any other surface that is in contact with water Its use in zones 0 or 1 in bathrooms is totally prohibited seek advice from a qualified electrician 16 For greater safety this appl...

Page 4: ...structions in the MAINTENANCE section because if water enters the air grilles it could seriously damage the device Do not insert any object through the grille or inside the device This radiator is des...

Page 5: ...ust be installed only within Zones 2 or Outside Zones Zone3 according BS 7671 Requirements for Electrical Installations Section 701 The installation of this appliance within Zones 0 or 1 of a bathroom...

Page 6: ...g to the base outlet Check the condition of your electrical installation and connection cables This appliance doesn t require earthing connection due it has double electrical insulation Contact a lice...

Page 7: ...onsumption Control Radiator Open Windows Function 1 1 Screen 1 Operation Mode The active operation mode is displayed in the box 2 Programme Number P1 to P9 U1 to U4 or System Settings Menu 01 to 11 3...

Page 8: ...turn off for a few seconds ATTENTION In case the device s power disconnects the memory of the settings recorded lasts for approximately one hour After that time we recommend you check the settings ins...

Page 9: ...d with keys and and confirm with the OK key Factory setting 21 C The Timer symbol will flicker and you will see the hour day number count down until the end of the period 3 2 Manual Comfort Mode The M...

Page 10: ...default value It can be set in System Settings menu section 5 number 05 3 6 Program Mode Once you have selected the Program mode you can choose between nine preset programs P1 to P9 These are defined...

Page 11: ...be reduced How to edit a user programme The programming is carried out in 30 minutes slots 30 minutes 1 hour The programme editing always starts on the first day of the week 01 Monday The key activate...

Page 12: ...hour and one day durations selected 4 Specials Functions 4 1 Keypad Lock Use this function to prevent any change in the thermostat setting This is useful in areas such as children s bedrooms or public...

Page 13: ...Degrees 02 Time selection 24 00 12 00 AM Antemeridian PM Post meridian 03 Automatic summer winter time change The time will change automatically The time must be changed manually You must correctly s...

Page 14: ...e radiator will recalibrate to ensure you achieve the comfort temperature at the time you want it 07 Open window automatic detection This function allows automatic detection of window opening see sect...

Page 15: ...han 2 hours Check the wire pilot function Only France THERMAL SAFETY In the case of overheating a safety device automatically cuts the radiators operation After cooling the radiator will automatically...

Page 16: ...TO P9 P1 Morning Afternoon Weekend P2 Morning Noon Evening Weekend P3 Week Weekend P4 Afternoon Weekend P5 Morning Afternoon Bathroom P6 Morning Afternoon Weekend P7 7H 19H Office P8 8H 19H Saturday...

Page 17: ...declare that the following equipment complies with all the essential requirements for health and safety of European Directives 2014 30 EC EMC DIRECTIVE 2014 35 EC LV DIRECTIVE 2011 65 UE RoHS DIRECTIV...

Page 18: ...e stage heat output and no room temperature control NO Maximum continuous heat output Pmax c 2 kW Two or more manual stages no room temperature control NO Auxiliary electricity consumption with mechan...

Page 19: ...ith presence detection NO Maximum continuous heat output Pmax c 1 5 kW room temperature control with open window detection YES Auxiliary electricity consumption with distance control option NO At nomi...

Page 20: ...0 75 kW Maximum continuous heat output Pmax c 0 75 kW Auxiliary electricity consumption At nominal heat output elmax 0 75 kW In standby mode elSB 0 0005 kW Contact details HERMANOS JULI N M S L Head...

Page 21: ...o optimise the recycling of the components and materials that comprise it and reduce the impact on human health and the environment The crossed out wheeled bin is marked on all Electrical and Electron...