HCC-96RF-C(S) Series
HITROL CO.,LTD.
8
Maintenance
Failure Check
Safety and
Environment
The life span of key parts depends on user’s environment and can be used optimally through
periodic check. Therefore, regular inspection ensures optimal performance of product, so take
regular inspection and maintenance at least every year. Inspection of the appearance of the product
shall be visually checked to see if there is any damage, and the attachment of the medium or
foreign substances to the sensor will make it worse, so they shall be removed regularly.
■ Precautions for Use
- Make sure to connect the product and vessel using required tools for sure.
- Keep the lock key safe and make sure that it is locked.
- Do not apply high impact to the product.
■ Precautions for Wiring
- Make sure to wire contacts correctly.
- Wire and supply the power to the product after checking the specifications.
- Incorrect power voltage may cause damage to the product.
- Pay attention to prevent electric shock.
■ Disposal of Product
- Make sure to separate the amplifier and main unit from housing before disposing
the products. Also, the amplifier shall be detached and discard the metal and non-
metallic materials. No part (ex. Mercury switch) has influence on the environment, so
no special attention is required.
If there is a problem with operation, check the following first.
■ Is power voltage connected correct?
■ Is power voltage supplied according to specifications correct?
■ Is cable wiring correct?
■ Is the Fail-Safe Mode setting correct?
■ Does the green LED turn on?
Turn off the power of the product for maintenance.
HEAD External Grounding (PBT)
HEAD External Grounding (AL.C)
External Grounding
4㎟ (4mmSQ)