1) If the unit has an active alarm, the button

lights up. 

By pressing said button, the sound alarm shuts off.

2) Pressing it again, if the alarm is solved, will erase said

alarm.

3) In case the alarm is not solved, consult your refrigerator

technician.

When you have just one terminal to operate various machi-
nes, it is called a LAN-NETWORK 

To access each one of the units, press the buttons

+

y cambiar entre las diferentes unidades 

presentes en la RED-LAN.

10.14   Ref. 200587 Rev. 101  D.L.: B-34,641-06  Gràfiques Ferpala, s.l.  Eduard Toldrà, 111   08800 Vilanova i La Geltrú  Tel. 93 893 70 11

Reservado el derecho a efectuar modificaciones sin previo aviso.

Specifications subject to change without previous notice.

MANDO pGD / pGD CONTROL

MANUAL DEL USUARIO / USER’S MANUAL

CONFIGURACION / CONFIGURATION

ANULACION ALARMAS

Unidad: 01

Representa el número de unidad a la cual
esta conectado el terminal.

12:00

Indica la hora real (solo si se ha instalado la
tarjeta reloj, esta configuración es opcional)

INV/VER    

Indica el modo e funcionamiento de la unidad
INV: bomba de calor VER: frió

Al

Indica si la unidad tiene alguna alarma activa

20.0 ºC

Indica la temperatura de retorno

050.3 % HR Indica la humedad medida en los sensores

Unidad Off

Indica el estado de la maquina, pueden salir
varios rótulos Unidad off por fase horario-
Unidad Off Remoto                                

1) Si la unidad tiene alguna alarma activa se ilumina el 

botón

al pulsar dicho botón se elimina la alarma 

acústica.

2) A una segunda pulsación si la alarma esta solventada, se

borrara dicha alarma.

3) En caso de no solventarse, avise a su técnico frigorista.

Cuando se disponga de un solo terminal para actuar sobre
varias maquinas, le denominamos RED-LAN 

Para acceder a cada una de las unidades apretar a la vez

los botones

+

y cambiar entre las diferentes 

unidades presentes en la RED-LAN.

REPRESENTACION UNIDAD PRINCIPAL

ANNULLING ALARMS

LOCAL NETWORK

Unit: 01

Represents the number of the unit that is con-
nected to the terminal.

12:00

Indicates the real time (only if the clock card has
been installed, this configuration is optional)

WIN/SUM     Indicates the mode and operation of the WIN

unit: SUM heat pump: cold

Al

Indicates whether the unit has an active alarm

20.0 ºC

Indicates the return temperature

050.3 % HR Indicates the humidity measured at the sensors

Unit Off

Indicates the state of the machine, various Unit
off signs may appear per time phase-
Remote Unit Off

MAIN REPRESENTATION UNIT

Ref 200587 Rev100 mando pGD Es_En  26/6/06  12:48  Página 8

Summary of Contents for pGD

Page 1: ...MANUAL DEL USUARIO USER S MANUAL MANUAL DEL USUARIO USER S MANUAL 10 14 Ref 200587 Rev 101 MANDO pGD pGD CONTROL...

Page 2: ...unto de consigna temperatura y HR 5 Cambio verano invierno 6 Paro Marcha unidad 7 Anulaci n alarmas 8 Red local 8 Representaci n unidad principal 8 CONTENTS Generalities 3 Front view 4 Changing the te...

Page 3: ...ierno y horarios en el caso de incorporar una tarjeta reloj sin necesidad de password Visualizaci n en pantalla de las posibles alarmas del sis tema y aviso ac stico de las mismas GENERALIDADES GENERA...

Page 4: ...s de los par metros de regulaci n TECLA ENTER confirmaci n de los valores introdu cidos FLECHA HACIA ABAJO para la gesti n de los men s y modificaci n de valores de los par metros de regulaci n VISTA...

Page 5: ...s la tecla 5 En el submen consigna regulaci n de temperatura si apretamos bajar entramos en el siguiente submen Consigna regulaci n Humedad 50 0 Para modificaci n de valores seguir los pasos 3 y 4 6 U...

Page 6: ...the values entered press the key 5 Once the values are modified press the button and return to the previous menus CAMBIO VERANO INVIERNO 1 Apretar la tecla se mostrara la anterior pantalla 2 Escogemos...

Page 7: ...ajar establecemos el paro o marcha y para confirmar los valores introducidos apretamos la tecla 5 Una vez modificados los valores apretamos el bot n y volvemos a los men s anteriores STOP START UNIT 1...

Page 8: ...ma activa 20 0 C Indica la temperatura de retorno 050 3 HR Indica la humedad medida en los sensores Unidad Off Indica el estado de la maquina pueden salir varios r tulos Unidad off por fase horario Un...

Reviews: