![Hitecsa ACVIBA HE 35i Installation, Operation & Maintenance Manual Download Page 10](http://html1.mh-extra.com/html/hitecsa/acviba-he-35i/acviba-he-35i_installation-operation-and-maintenance-manual_2140071010.webp)
10
IOM_ACVIBA HE_35ia80i_207910_190501_EN
ACVIBA HE
AIR-AIR PACKAGED UNITS
COMPACT VERTICAL INVERTER
TECHNICAL SPECIFICATIONS
MOSAIC HE RANGE
35i
40i
45i
55i
70i
80i
INDOOR FAN
Type
Plug fan EC
Total number
1
2
Nominal airflow
m³/ h
6,500
8,500
9,600
11,000
13,000
17,000
Available pressure according to standard
(1)
Pa
150
200
Available static pressure (Nominal flow)
Pa
500
450
500
Available high pressure
(2)
(Max. flow)
Pa
1000
900
1000
OUTDOOR FAN
Type
Plug fan EC
Total number
1
2
Max. airflow
m³/ h
13,000
15,000
18,400
22,000
26,000
30,000
Available pressure according to standard
(1)
Pa
60
Available static pressure (Max. flow)
Pa
Up to 60 Pa
Available high pressure
(2)
(Max. flow)
Pa
250
200
550
550
250
200
DIMENSIONS AND WEIGHT
Length
mm
1,423
2,800
Width
mm
854
Height
mm
2,491
Weight
kg
517
523
972
972
1007
1024
SOUND POWER LEVEL (Lw)
Exterior radiation Standard unit
dBA
86.5
90.8
74.6
85.3
89.2
93.7
Exterior radiation Unit running at 50%
(4)
dBA
83.0
82.1
64.4
72.5
86.0
86.0
SOUND PRESSURE LEVEL at 5 m
(3)
(Lp)
Exterior radiation Standard unit
dBA
65.1
69.4
53.1
63.8
67.7
72.3
Exterior radiation Unit running at 50%
(4)
dBA
61.5
60.6
43.0
51.1
64.6
64.6
(1)
According to the EN 14511 standard.
(2)
Option
(3)
Directivity = 2 (in semi-sphere)
(4)
The unit is running with the fan at the 2nd speed level with a partial charge of 50% of its capacity.