background image

6

9

MECHANICAL P

ACKAGE  DRA

WING

NOTE

T

H

FA

C

T

O

R

Y

 D

E

FA

U

LT V

A

LU

E

S

 AR

E S

H

O

W

N

 IN

 

RE

D

.

S

L

O

W T

IM

E

B

A

S

E

 6

75H

z

FA

ST

 T

IM

E

B

A

SE

 2

7

0

0

H

z

C

O

M

P

U

TE

R

 SET V

A

L

U

E

P

O

TEN

TIO

M

ET

ER

 SE

T

0 T

O

 5v

dc 

SE

T

0 T

O

 20

m

a S

E

T

D

IF

F

. SE

T

=

1N

P2

+

F

IXED

 S

E

TEM

P

D

E

A

DB

A

ND CON

T

R

O

L

PI

D C

O

N

T

R

O

L

C

OM

P

U

T

E

R

 C

O

NT

R

O

L

H

E

A

T

 W

P

1+

 AND

 WP

2-

H

E

AT

 W

P

2+

 AND

 WP

1-

N

O AL

AR

M

S

 P

ICKE

D

SE

T

 T

R

AC

KI

N

G

 A

L

ARM

S

F

IX

E

D

 VAL

U

E

 AL

AR

M

S

COMP

U

T

E

R

 C

O

NT

R

O

L

L

E

D

N

O S

H

U

T

DOW

IF

 AL

A

R

M

M

A

IN

 OU

T

 SH

U

T

DO

WN

 I

F

 AL

A

R

C

ONT

R

O

L

 S

E

NS

OR

INP

U

T

2 S

E

NS

OR

UT

P

U

T

OW

E

R

 %

M

o

d

el 5C7

-36

2

 M

en

u

 Tree

R

S-232 C

o

mm

unic

a

ti

on

s

C

OM

1

COM2

COM3

COM4

A

LA

R

M

 LA

T

C

H

 O

F

F

A

LA

R

M

 LA

T

C

H

 O

N

D

EG

 F

DE

G C

T

S

67 Se

n

so

20

°C t

o

 1

0

0

°C

T

S

141 Se

n

so

40

°C t

o

 7

0

°C

TC-136

N/

A

H

iTEC

H

Te

ch

no

lo

gi

es

, In

c.

Summary of Contents for TC-136

Page 1: ...ERMOELECTRIC MODULE TEMPERATURE CONTROLLER HiTECH Technologies Inc 301 Oxford Valley Road Yardley PA 19067 7706 Tel 215 321 6012 Fax 215 321 6067 Technical support 800 755 4507 or 888 NIVELCO Email in...

Page 2: ...NOTES 16...

Page 3: ...als are expressed in repeats minute The acceptable range for the TC 136 is 0 01 to 10 repeats minute Start with a setting determined by the following formula Integral Reset 1 2 period Note Period is e...

Page 4: ...atisfactorily with only the P and I values used Start the tuning process by setting the Integral and Derivative functions to zero Proportional Bandwidth is defined as the temperature range around the...

Page 5: ...zontal or vertical orientation Input and output connections are accessible via screw type terminal strips fast on terminals and a 100 center connector TECHNICAL DESCRIPTION Model TC 136 is capable of...

Page 6: ...rm condition or the main power may be shut down 3 24 NOTE Refer to the Menu Tree in this manual for the factory default settings for the following parameters 25 The FIXED SET TEMP is the set temperatu...

Page 7: ...user activation of the alarm relay via the PC 16 The POWER OUT SHUT DOWN IF ALARM menu key provides two selections NO SHUT DOWN IF ALARM which will let the power output stage of the controller to con...

Page 8: ...r PC monitor 7 NOTE If you receive an error message please refer to Appendix A 8 All selections are made from this menu screen In the PC COMMUNICATIONS box select the COMM PORT 1 through 4 which will...

Page 9: ...TROL PID CONTROL COMPUTER CONTROL HEAT WP1 AND WP2 HEAT WP2 AND WP1 NO ALARMS PICKED SET TRACKING ALARMS FIXED VALUE ALARMS COMPUTER CONTROLLED NO SHUTDOWN IF ALARM MAIN OUT SHUTDOWN IF ALAR CONTROL S...

Page 10: ...7 8 CUSTOMER HOOK UP DRAWING EXPANSION CONNECTOR WIRING DIAGRAM TC 136...

Reviews: