background image

Introduction

12V

Instruction manual 

EN

Thank you for your choice of the HiTEC multicharger X4 MICRO SE. This unit is simple to use but it´s 

operation does require some knowledge on the part of the user. Please read this entire operating manual 

completely and attentively before using this product, as it covers a wide range of information on operating 

and safety.
The multicharger X4 MICRO SE employs the circuit that features four totally independent but identical power 

outputs which are powered 5W each. It is designed for charging single cell LiPo. Insert the battery lead to 

the right connector in each port, the charger will charge 4 batteries at the same time. And the charging 

current can be adjusted from 0.05 to 1.2A by dial, the charging capacity and cell voltage can be displayed in 

the digital LED indicator.

# 1-00689

Errors and omissions excepted   © MULTIPLEX

Specifikation
AC / DC Input

100-240V  /  11-15V

Charge circuit power

4x 5,22W ± 10%

Charge current range 

0.05 - 1.2A ± 10%

Battery type

4x 1 Zelle LiPo / LiHV

Battery connector type

Micro / JST / MX / mCPX

Working temperature

0-50°C

Net weight

245 g

Dimension

130x94x50mm

JST

mCPX

Micro

MX

4-Digital LED 

Indicator

Charging Status 

LED Indicator

Rotary Dial  

for Setting  

Charging Current  

Start/Stop Button

AC Input Power Port 

100-240V

DC Input 

Power Jack 

11-15V

When using AC power source

1. Insert the AC power cord into the charger.
2. Insert the AC power cord into a wall socket (100-240V).
3. When charger is powered on, 4 status LEDs will blink 

once with one beep and all digital LED indicators will 

display 8888. After that, 4 LEDs will extinguish and all 

digital Displays will show the charging current which 

indicates the charger is ready to charge.

Caution: 

Each charging port can only charge one kind 

of battery at the same time.

When using 12V lead acid battery

Using DC cable attaching to car battery

When there is an error, the LED will blink red twice per second with an audible sound.  

After ten times of blinking, the red LED will stay on and the digital LED will display the error code.

 · Four independent ports can be used at the same time
 · Four different kinds of battery connectors at each port
 · Four independent functioning charging circuits
 · Four independent digital LED Displays
 · LED and audible sound indicate charging status
 · Adjustable charging current from 0.05 to 1.2A
 · AC/DC Dual Power Input
 · Maximum protection: short circuit protection; over current protection; battery reverse polarity protection 

and DC input voltage protection

Features

Charging

Error messages

Error 

Error Message

-11-

Dead cell or the voltage of the cell is either too high or too low for safe charging.

-22-

The battery polarity is connected incorrectly.

-33-

The battery connection is wrong. 

-44-

Short circuit or over current in the battery. 

-55-

The DC input voltage is either too high or too low. 