HITEC multi cahrger X4 AC Plus Instruction Manual Download Page 19

17

16

This screen, you can set up the current and voltage of the 

battery pack. Charging and discharging will bring the batter-

ies to the storage level.

This screen shows the real-time status of the charge or 

discharge process. Press the

 BATT TYPE/STOP

 key once to 

stop the charging process.

The setting of the discharge current on the left cannot exceed 

1C, and the setting on the right cannot be under the voltage 

recommended by the manufacturer to avoid deep discharg-

ing. Press the 

START/ENTER

 key for more than 3 seconds to 

start discharging.

This shows the real-time status of discharging; you can press 

the 

BATT TYPE/STOP

 key to stop discharging.

Charging NiCd or NiMh Batteries 

This program is for charging NiCd/NiMH batteries typically 

used in an R/C model application. Press the START/ENTER 

key until the parameter you want to change begins to blink 

then use the INC or DEC keys to change the value. Press the 

START/ENTER key to store the setting.

This screen shows the real-time status of charging. You can 

press the BATT TYPE/STOP key to stop the charge process.

NOTE

 

During the discharge process the X4 AC Plus’s Microprocessor monitors the voltage of 

each cell during the Storage Mode or Discharge process. If the voltage of any cell is 

abnormal, the charger will display an error message and immediately terminate the 

program. Before disconnecting the battery review the error message then press the INC 

button to display which cell is.

Charging Lithium Batteries in the Storage Mode

The Storage Mode function is for charging/discharging batteries that will not be used 

immediately or that will be stored for a period of time. The program is designed for charg-

ing or discharging batteries to a specific voltage level depending on the type of battery 

(Li-ion = 3.75V, LiPo = 3.85V and LiFe = 3.3V) The program will begin to discharge if the 

original state of the battery exceeds the voltage level for storage.

Lithium batteries are recommended to be discharged partially rather than fully. Frequent 

full discharging should be avoided if at all possible. Instead, charge the battery more often 

or use a battery of larger capacity. Full capacity cannot be reached until it has been 

subjected to 10 or more charge cycles. The cyclic process of charge and discharge will 

optimize the capacity of the battery pack.

There are two methods of charging NiCD and NiMh batteries, Manual or Auto Mode. When 

in the NiMh or NiCd Program Select screen you can change modes by pressing the 

START/ENTER

 key until the current field begins flashing then press 

INC

 and 

DEC

 simulta-

neously to switch between Auto and Manual Mode. using the charge current you set up. In 

the “auto” mode, you should set the upper limit of the charge current to avoid damage caused 

by excessive charge current. This is especially important for low quality batteries that have 

low resistance and capacity. In the “manual mode” the charger will only charge at the current 

you set.  Note the following charger / discharge specifications for NiCd and NiMh Batteries.

 

Nominal Voltage level:

 1.2V/cell

 

Allowable Fast Charge Current:

 1C-2C (depends on performance of cell)

 

Discharge Voltage Cut Off Level NiCd:

 0.85V per cell

 

Discharge Voltage Cut Off Level NiMh:

 1.0V per cell

Error Message Display

 

 

CHARGING/ DISCHARGING AND CYCLING NiCd OR NiMh BATTERIES 

This screen shows that the processor detected the voltage of 

one on the cells is too low.

This screen shows the 4th cell was damaged. If the cell is 

disconnected or not present the reading of the voltage will be 

zero.

Error Message Display  

INC

This screen shows that the processor detected the voltage of 

one on the cells is too low.

This screen shows the 4th cell was damaged. If the cell is 

disconnected or not present the reading of the voltage will be 

zero.

CHARGING LITHIUM CHEMISTRY (LiPo/Lilo/LiFe) TYPE BATTERIES  

DISCHARGING LITHIUM CHEMISTRY (LiPo/Lilo/LiFe) TYPE BATTERIES

DISCHARGING LITHIUM CHEMISTRY (LiPo/Lilo/LiFe) TYPE BATTERIES

Number

of Cells

Charge or

Discarge

Current

Battery

Voltage

Supplied

Capacity

Elapsed

Time

DEC INC

DEC INC

DEC INC

DEC INC

‘>3 seconds’

Batt Type

Stop

Start

Enter

 INC

‘>3 seconds’

Batt Type

Stop

Start

Enter

Number

of Cells

Elapsed

Time

Discharge

Current

Battery

Voltage

Discharged

Capacity

DEC INC

DEC INC

‘>3 seconds’

Batt Type

Stop

Start

Enter

Battery

Type

Elapsed

Time

Charge

Current

Battery

Voltage

Charged

Capacity

Summary of Contents for multi cahrger X4 AC Plus

Page 1: ......

Page 2: ...mation 13 Charging Lithium Chemistry LiPo LiIo LiFe Type Batteries 13 Discharging Lithium Chemistry LiPo LiIo LiFe Type Batteries 16 Charging Discharging and Cycling NiCd or NiMH Batteries 17 Charging...

Page 3: ...car battery or a 11 15 V 20 amp minimum DC power supply The Hitec X4 AC Plus is simple to use but the operation of a sophisticated automatic charger such as the X4 AC Plus does require some knowledge...

Page 4: ...1 10 Lead Acid cells 2V 20V 300mA Automatic negative delta peak method Automatic voltage dependent CC CV process 8 9 x 6 7 x 2 6 3 4 lbs Operating Voltage Range DC 11 15 Volt The Hitec X4 AC Plus all...

Page 5: ...Port Pitch 2 54mm Universal Balancing Port Pitch 2 54mm AC Input Power Port T emp Sensor PC Link Available for 1 3 only output T emp Sensor PC Link Available for 2 4 only output Ventilation Fan with...

Page 6: ...process will automatically end Charges Most Popular Lithium Batteries The X4 AC Plus is compatible with the three most common Lithium chemistry batteries Li Ion LiPo and LiFe Multiple Lithium Battery...

Page 7: ...h is not included in our package 10 User Customizable Presets The X4 AC Plus features 10 individually customizable presets so the user can store the charge and discharge parameters for any particular...

Page 8: ...as it covers a wide range of information on operation and safety Never leave the charger unattended when it is connected to its power supply If any malfunction is found TERMINATE THE PROCESS AT ONCE a...

Page 9: ...by the battery manufacturer Only batteries that are expressly stated to be capable of quick charge should be charged at rates higher than the standard charge current Connect the battery to the termina...

Page 10: ...N The Hitec X4 AC Plus comes with a built in switching power supply allowing you to connect it directly to a 120 VAC wall socket using the supplied AC power cord The charger can also be powered by a 1...

Page 11: ...es supported by the X4 AC Plus LiFe 3 3V Lilo 3 6V or LiPo 3 7V If you plan to use one type of Lithium chemistry battery you can set the default here WARNING Make sure when you connect your battery th...

Page 12: ...ting then press INC to move on to the next parameter Waste Time Setting When charge discharge cycling a battery the battery will become warm You can set a time delay ranging from 0 to 60 minutes after...

Page 13: ...ll end forcibly to protect the input source Once you have established the desired settings press Start Enter to confirm the setting You have now set the initial user settings You can repeat this proce...

Page 14: ...12 PROGRAM FLOW CHART...

Page 15: ...the present input voltage going to the charger When the battery is connected to the balancing port you can check the voltage of each cell in the battery pack The program can display the voltages of u...

Page 16: ...time status during the charge process Press the BATT TYPE STOP key once to stop the charge process NOTE When you want to change the settings press the START ENTER key to make it blink then use the DEC...

Page 17: ...number of cells the processor detects as S If both numbers are identical you can start charging by pressing the START ENTER button If not press the BATT TYPE STOP button to go back to the previous sc...

Page 18: ...s to a specific voltage level depending on the type of battery Li ion 3 75V LiPo 3 85V and LiFe 3 3V The program will begin to discharge if the original state of the battery exceeds the voltage level...

Page 19: ...een Auto and Manual Mode using the charge current you set up In the auto mode you should set the upper limit of the charge current to avoid damage caused by excessive charge current This is especially...

Page 20: ...of the battery being charged or discharged Use the INC or DEC keys to scroll through the results of each cycle This program is only suitable for charging a lead acid PB type battery with a nominal vo...

Page 21: ...the Default User Preferences Setup section of this manual to set up this feature Charging Lead Acid Pb Batteries Set up the discharge current on the left and the nominal voltage on the right The disch...

Page 22: ...ls and a capacity of 3000mAh When you have completed this process press and hold the START ENTER key for 3 seconds to enter the charge discharge setup screen Set up the charge current in the manual mo...

Page 23: ...tec RCD USA customer service department immediately The voltage is lower than which is set check the number of cells in the battery pack The voltage is higher than which is set check the number of cel...

Page 24: ...to any electronic components or internal assemblies RECOMMENDED ACCESSORIES Conform Conform Conform Conform CE LVD CE EMC EN60335 FCC VOC FCC Part 15B Electromagnetic compatibility EMC Part 6 3 Generi...

Page 25: ...IED WARRANTY RELATING TO THIS PROD UCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRANTY OF MERCHANABILITY OR FITNESS FOR A PARTICUALR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATI...

Page 26: ...o Battery Type Charge Mode Charge Discharge Current Charge Discharge Voltage 1 2 3 4 5 Preset No Battery Type Charge Mode Charge Discharge Current Charge Discharge Voltage 1 2 3 4 5 Preset No Battery...

Page 27: ...25 USER NOTES...

Page 28: ...All specifications and figures are subject to change without notice...

Reviews: