HITEC multi cahrger X4 AC Plus Instruction Manual Download Page 14

13

12

You can view a variety of information on the LCD screen during the charge and 

discharge process. Press the 

DEC

 key to display and scroll through these settings.  

When connected to the balancing port you can monitor the voltage of each individual 

cell by pressing the 

INC

 key.

DEC

DEC

DEC

DEC

DEC

When the program is completed, the final voltage is displayed.

When the capacity cutoff function is turned on, the capacity value is 

displayed.

When the safety timer is displayed, the duration of time in minutes is 

displayed.

This screen shows that the temperature cutoff function is turned on.

When the temperature probe is used, the external temperature will 

be displayed.

This shows the present input voltage going to the charger.

When the battery is connected to the balancing port, you can check 

the voltage of each cell in the battery pack. The program can display 

the voltages of up to 6 batteries.

CHARGING LITHIUM CHEMISTRY (LiPo/Lilo/LiFe) TYPE BATTERIES  

NOTICE

  

This program is only suitable for charging/discharging Lithium chemistry batteries. The 

X4 AC Plus was designed to only charge three kinds of Lithium batteries, Lithium Ferrite 

(LiFe), Lithium Ion (LiIo) and Lithium Polymer (LiPo). It is very important that you deter-

mine the type of battery you are charging and set the charging parameters correctly. It is 

important that the nominal voltage, final voltage, and battery capacity be properly set for 

desired operation. Please refer to the following information regarding the different types 

of Lithium chemistry batteries.

PROGRAM FLOW CHART

 PROGRAM DISPLAY INFORMATION 

DEC

Summary of Contents for multi cahrger X4 AC Plus

Page 1: ......

Page 2: ...mation 13 Charging Lithium Chemistry LiPo LiIo LiFe Type Batteries 13 Discharging Lithium Chemistry LiPo LiIo LiFe Type Batteries 16 Charging Discharging and Cycling NiCd or NiMH Batteries 17 Charging...

Page 3: ...car battery or a 11 15 V 20 amp minimum DC power supply The Hitec X4 AC Plus is simple to use but the operation of a sophisticated automatic charger such as the X4 AC Plus does require some knowledge...

Page 4: ...1 10 Lead Acid cells 2V 20V 300mA Automatic negative delta peak method Automatic voltage dependent CC CV process 8 9 x 6 7 x 2 6 3 4 lbs Operating Voltage Range DC 11 15 Volt The Hitec X4 AC Plus all...

Page 5: ...Port Pitch 2 54mm Universal Balancing Port Pitch 2 54mm AC Input Power Port T emp Sensor PC Link Available for 1 3 only output T emp Sensor PC Link Available for 2 4 only output Ventilation Fan with...

Page 6: ...process will automatically end Charges Most Popular Lithium Batteries The X4 AC Plus is compatible with the three most common Lithium chemistry batteries Li Ion LiPo and LiFe Multiple Lithium Battery...

Page 7: ...h is not included in our package 10 User Customizable Presets The X4 AC Plus features 10 individually customizable presets so the user can store the charge and discharge parameters for any particular...

Page 8: ...as it covers a wide range of information on operation and safety Never leave the charger unattended when it is connected to its power supply If any malfunction is found TERMINATE THE PROCESS AT ONCE a...

Page 9: ...by the battery manufacturer Only batteries that are expressly stated to be capable of quick charge should be charged at rates higher than the standard charge current Connect the battery to the termina...

Page 10: ...N The Hitec X4 AC Plus comes with a built in switching power supply allowing you to connect it directly to a 120 VAC wall socket using the supplied AC power cord The charger can also be powered by a 1...

Page 11: ...es supported by the X4 AC Plus LiFe 3 3V Lilo 3 6V or LiPo 3 7V If you plan to use one type of Lithium chemistry battery you can set the default here WARNING Make sure when you connect your battery th...

Page 12: ...ting then press INC to move on to the next parameter Waste Time Setting When charge discharge cycling a battery the battery will become warm You can set a time delay ranging from 0 to 60 minutes after...

Page 13: ...ll end forcibly to protect the input source Once you have established the desired settings press Start Enter to confirm the setting You have now set the initial user settings You can repeat this proce...

Page 14: ...12 PROGRAM FLOW CHART...

Page 15: ...the present input voltage going to the charger When the battery is connected to the balancing port you can check the voltage of each cell in the battery pack The program can display the voltages of u...

Page 16: ...time status during the charge process Press the BATT TYPE STOP key once to stop the charge process NOTE When you want to change the settings press the START ENTER key to make it blink then use the DEC...

Page 17: ...number of cells the processor detects as S If both numbers are identical you can start charging by pressing the START ENTER button If not press the BATT TYPE STOP button to go back to the previous sc...

Page 18: ...s to a specific voltage level depending on the type of battery Li ion 3 75V LiPo 3 85V and LiFe 3 3V The program will begin to discharge if the original state of the battery exceeds the voltage level...

Page 19: ...een Auto and Manual Mode using the charge current you set up In the auto mode you should set the upper limit of the charge current to avoid damage caused by excessive charge current This is especially...

Page 20: ...of the battery being charged or discharged Use the INC or DEC keys to scroll through the results of each cycle This program is only suitable for charging a lead acid PB type battery with a nominal vo...

Page 21: ...the Default User Preferences Setup section of this manual to set up this feature Charging Lead Acid Pb Batteries Set up the discharge current on the left and the nominal voltage on the right The disch...

Page 22: ...ls and a capacity of 3000mAh When you have completed this process press and hold the START ENTER key for 3 seconds to enter the charge discharge setup screen Set up the charge current in the manual mo...

Page 23: ...tec RCD USA customer service department immediately The voltage is lower than which is set check the number of cells in the battery pack The voltage is higher than which is set check the number of cel...

Page 24: ...to any electronic components or internal assemblies RECOMMENDED ACCESSORIES Conform Conform Conform Conform CE LVD CE EMC EN60335 FCC VOC FCC Part 15B Electromagnetic compatibility EMC Part 6 3 Generi...

Page 25: ...IED WARRANTY RELATING TO THIS PROD UCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRANTY OF MERCHANABILITY OR FITNESS FOR A PARTICUALR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATI...

Page 26: ...o Battery Type Charge Mode Charge Discharge Current Charge Discharge Voltage 1 2 3 4 5 Preset No Battery Type Charge Mode Charge Discharge Current Charge Discharge Voltage 1 2 3 4 5 Preset No Battery...

Page 27: ...25 USER NOTES...

Page 28: ...All specifications and figures are subject to change without notice...

Reviews: