English
5
APPLICATION
For charging the HITACHI BATTERY
䡬
BCL1415, EBL1430, BCL1430, EBM1430R, BCL1815,
EBM1830
CAUTION:
䡬
If the batteries are inserted in the reverse direction,
not only recharging will become impossible, but it
may also cause problems in the charger such as
a deformed recharging terminal.
3. Charging
When inserting a battery in the charger, the charge
status lamp will light up continuously in red.
When the battery becomes fully recharged, the
charge status lamp will blink in red. (At 1-second
intervals.) (See
Table 1
)
(1) Lamp indication
The indications of the lamp will be as shown in
Table 1
, according to the condition of the charger
or the rechargeable battery.
CHARGING
Before using the power tool, charge the battery as
follows.
1. Connect the charger’s power cord to the receptacle.
When connecting the plug of the charger to a
receptacle, the charge status lamp will blink in red.
(At 1-second intervals).
2. Insert the battery into the charger.
Firmly insert the battery into the charger till it
contacts the bottom of the charger and checking
the polarities as shown in
Fig. 1
.
Table 1
Indications of the lamp
Before
Blinks
Lights for 0.5 seconds. Does not light
charging
for 0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
Blinks
Lights for 0.5 seconds. Does not light
for 0.5 seconds. (off for 0.5 seconds)
Flickers
Lights for 0.1 seconds. Does not light
for 0.1 seconds. (off for 0.1 seconds)
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Lights
Lights continuously
Overheat
standby
Overheat
lamp
(green)
While
charging
Charging
complete
Charging
impossible
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Charge
status lamp
(red)
Malfunction in the
battery or the charger
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in the table below, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 2
(3) Regarding recharging time
Table 3
shows the recharging time required
according to the type of battery.
NOTE:
The recharging time may vary according to the
ambient temperature.
4. Disconnect the charger’s power cord from the
receptacle.
5. Hold the charger firmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger
after use, and then keep it.
Temperatures at which
Rechargeable batteries
the battery can be
recharged
BCL1415, EBL1430,
BCL1430, EBM1430R,
0°C — 50°C
BCL1815, EBM1830
Table 3
Recharging time (approx. min.) at 20°C
Battery capacity (Ah)
Li-ion BATTERY
1.5 Ah
3.0 Ah
EBL1430 (4 cells)
14.4V
BCL1415 (4 cells) 30min.
BCL1430 (8 cells)
65min.
EBM1430R (8 cells)
18V
BCL1815 (5 cells) 30min. EBM1830 (10 cells) 65min.
Battery
Voltage
01Eng_UC18YGL_WE_NE
07/10/31, 17:23
5