3 Control functions
Smart function
SMGB0135 rev.0 - 06/2020
29
3
After selecting the Smart Function (HP Block or SG Ready) it is necessary to select the appropriate input on the I/O
menu:
Input for SG Ready or HP Block
Input for SG Ready
3.12.1 SG Ready Function
The SG Ready is awarded to the heat pump series, to control technology by integrating the individual heat pump.
Allows in a smart grid by using two digital inputs establishing an unidirectional connection and allowed for four different
operation modes:
SG Input 1
SG Input 2
Action
Description
Open
Open
Standard HP mode
SG is not activated.
Close
Open
External blocking mode
Heat Pump is forbidden when signal is active
Open
Close
Low price mode
Increase DHWT Temperature setting by + 7ºC
Close
Close
Overcapacity mode
Tdhws (Setting temperature) =Tdhwmax (Maximum water temperature)