– 12 –
TRIPLE SYSTEM MULTI R.A.C.
RAM-53QH5
CONNECTING POSISION TO BE ABLE TO INSTALL
POSSIBLE COMBINATIONS
TO INSTALL
(kW)
CONNECTING POSITION ON
OUTDOOR UNIT
(VALVE DIAMETER)
(mm)
No.1
No.2
SUITABLE ROOM SIZE
TO INSTALL
(m
2
)
No.3
6.35/9.52D
6.35/9.52D
6.35/9.52D
TWO UNITS
THREE UNITS
1.8+1.8+1.8
1.8+1.8+2.5
(8-12) + (8-12) + (8-12)
(8-12) + (8-12) + (11-17)
1.8
1.8
1.8
1.8
1.8
2.5
1.8+1.8
1.8+2.5
1.8+3.5
1.8+5.0
2.5+2.5
2.5+3.5
(8-12) + (8-12)
(8-12) + (10-16)
(7-9) + (15-22)
(6-9) + (18-27)
(12-15) + (12-15)
(11-14) + (14-18)
1.8
1.8
1.8
1.8
2.5
2.5
1.8
2.5
3.5
5.0
2.5
3.5
3.5+3.5
(13-16) + (13-16)
3.5
3.5
2.5+5.0
(10-12) + (18-20)
2.5
5.0
2.5, 3.5, 4.0, 5.0 means indoor units cooling capacity class.
(1) Marking
: needs flare adapter (9.52 12.7D): Part No. TA261D-4 001
(2) Suitable room size is determined based on the conditions below:
• Climate is in the temperate zone like Tokyo, Japan.
• For usual residential use.
• Smaller figure is for light construction which means light thermally sealed.
• Larger figure is for heavy constructions, which means well thermally sealed.
1.8+1.8+3.5
(7-11) + (7-11) + (14-21)
1.8
1.8
3.5
1.8+2.5+2.5
(7-11) + (10-15) + (10-15)
1.8
2.5
2.5
2.5+2.5+2.5
(10-11) + (10-11) + (10-11)
2.5
2.5
2.5
Summary of Contents for RAM-52QH5
Page 16: ... 15 MODEL RAM 52QH5 ...
Page 17: ... 16 MODEL RAM 53QH5 ...
Page 30: ... 29 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 53QH5 ...
Page 36: ...CIRCUIT DIAGRAM MODEL RAM 52QH5 39 L C023 C022 C002 C001 C025 C024 N ...
Page 37: ...CIRCUIT DIAGRAM MODEL RAM 53QH5 41 L C023 C022 C002 C001 C025 C024 N ...
Page 40: ... 45 ...
Page 42: ... 49 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 43: ... 51 ...
Page 44: ... 53 ...
Page 45: ... 55 ...
Page 46: ... 57 ...
Page 58: ... 69 REFRIGERATING CYCLE DIAGRAM RAM 52QH5 ...
Page 59: ... 70 REFRIGERATING CYCLE DIAGRAM RAM 52QH5 ...
Page 60: ... 71 REFRIGERATING CYCLE DIAGRAM RAM 53QH5 ...
Page 61: ... 72 REFRIGERATING CYCLE DIAGRAM RAM 53QH5 ...
Page 64: ... 75 5A ...
Page 67: ... 78 3 System power Module Circuit ...
Page 71: ... 82 ...
Page 72: ... 83 5 Reversing valve control circuit Fig 5 1 ...
Page 87: ... 101 ...
Page 88: ... 102 ...
Page 94: ... 108 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 95: ... 109 ...
Page 96: ... 110 ...
Page 98: ... 112 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Page 99: ... 113 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 53QH5 MODEL RAM 52QH5 ...
Page 104: ...HITACHI PM NO 0428E Printed in Malaysia RAM 52QH5 RAM 53QH5 ...