The temporary switch is used to operate the air conditioner temporarily when the wireless remote control
is lost or faulty.
The air conditioner operates in the previous mode at the previously set temperature. However, when the
power switch is set to OFF, it starts automatic operation.
R403
5V
R406
C404
90
1
2
3
4
5
0
0 10 20 30 40
8. Room Temperature Thermistor Circuit
A room temperature thermistor circuit is shown in Fig. 8-1.
According to room temperature, the voltage of point becomes as it is shown in Fig.8-2.
Microcomputer
Room Temperature
Thermistor
V
oltage of point
(V)
(
㷄
)
Room temperature
Room
temperature input
Fig. 8-1
Fig. 8-2
䃢
A
0V
0V
5V
2
0
1
0
10 20 30 40
3
4
5
-10
R402
C403
R407
91
9. Heat Exchanger Thermistor Circuit
Heat exchanger temperature is noticed inside the room
(1) Preheating
(2) Low-temperature defrosts at cooling
and
dehumidification operation time.
(3) Not working of reversing valve or detection of opening of heat exchanger thermistor is controlled.
According to heat exchanger temperature, the voltage of point becomes as it is shown in Fig. 9-2.
Heat exchanger
thermistor
Microcomputer
Heat exchanger
input
Fig. 9-1
Fig. 9-2
V
oltage of point (V)
㷄
Heat temperature ( )
䃢
A
Fig. 7-1
TEMPORARY SW
MICROCOMPUTER
R405
SW211
Temporary
switch
0V
0V
C405
R663
5V
7. Temporary Switch Circuit
100
0V
0V
- 56 -
Summary of Contents for RAK-18QXB
Page 2: ... DANGER 2 ...
Page 24: ... 24 ...
Page 25: ... 25 ...
Page 26: ... 26 ...
Page 27: ... 27 ...
Page 28: ... 28 ...
Page 31: ...WIRING DIAGRAM RAK 18QXB RAK 25RXB RAK 35RXB RAK 50RXB 31 ...
Page 33: ...CIRCUIT DIAGRAM MODEL RAK 18QXB POWER FOR CLEANNESS 33 ...
Page 34: ...CIRCUIT DIAGRAM MODEL RAK 25RXB RAK 35RXB RAK 50RXB POWER FOR CLEANNESS 34 ...
Page 68: ...69 68 ...
Page 71: ...3 and page 38 7 71 ...
Page 73: ...57 73 ...
Page 74: ... 74 ...
Page 92: ...RAK 18QXB RAK 25RxXB HHAW NO 0088E 1 RAK 35RXB RAK 50RXB 92 ...