TROUBLESHOOTING
Filter cleaning is
performed after the
power is turned on
(after the circuit
breaker is switched
on or after power
failure)
• This is for filter cleaning operation check.
Filter cleaning
operation does not
start
( (FILTER CLEAN)
• During filter cleaning operation or within 5 minutes after the operation , the filter
cleaning operation will not restart to protect the device.
( (FILTER CLEAN) indicator lit for 1 second/off for 1 second, for 10 seconds)
• Is “filter cleaning operation prohibited” being set?
Please return to the filter cleaning operation setting.
• Are the micro mesh stainless filter, the dust catcher correctly installed?
( (FILTER CLEAN) indicator lit for 4 seconds/off for 1 second)
• Filter cleaning is not performed if the air conditioner operation is stopped by Sleep
Timer or Off Timer function. However, if the air conditioner is stopped by Sleep Timer
or Off Timer every time, filter cleaning will be performed approximately once a week.
Noise occurred
during filter
cleaning operation
• A whirring motor noise is generated due to driving of the cleaning unit.
• A sweeping sound is generated when the cleaning unit sweeps the dust.
Cleaning unit stops
halfway
•
( (
) indicator lit for 4 seconds/off for 1 second)
Micro mesh
stainless filter is
still dirty
• Filter may not be cleaned evenly depending on the environment in which the air
conditioner is used. To solve this problem, clean the micro mesh stainless filter.
• Depending on dust amount, the micro mesh stainless filter may not be completely
cleaned by manual filter cleaning operation performed at your preferred time while
filter cleaning operation is prohibited.
FILTER CLEANING OPERATION
indicator blinks)
FILTER CLEAN
Are the micro mesh stainless filter, the dust catcher correctly installed?
- 59 -
Summary of Contents for RAC-P25YHAB
Page 34: ...Mind mode Sleep Wind Mode F Wash OFF ECO Auto ON Sleep Wind Mode F Wash 34 ...
Page 36: ... 36 2 hours Swing button 1 5 hours 3 hours ...
Page 38: ...To combine Auto Off select Eco mode resumes operation with Eco mode is cancelled 38 ...
Page 40: ...SCENE CAMERA OPERATION 40 ...
Page 64: ... 64 MEMO ...
Page 65: ...2021 12 Version1 ...