– 99 –
TROUBLESHOOTING WHEN TIMER LAMP BLINKS.
Model RA
S
-
50Y
H4
Perform troubleshooting according to the number of times the indoor timer lamp and outdoor LD301 blink.
SELF-DIAGNOSIS LIGHTING MODE
Model: RA
S-50Y
H4
No.
Blinking of Timer lamp
Reason for indication
Possible cause
Reversing valve defective
When the indoor heat exchanger
temperature is too low in the
heating mode or it is too high in the
cooling mode.
Outdoor unit forced operation
When the outdoor unit is in forced
operation or balancing operation
after forced operation
Indoor/outdoor interface defective
When the interface signal from the
outdoor unit is interrupted.
Outdoor electrical assembly
defective.
Room thermistor or heat exchanger
thermistor is faulty
When room thermistor or heat
exchanger thermistor is opened
circuit or short circuit.
Over-current detection at the DC fan
motor
when over-current is detected at the
DC fan motor of the indoor unit.
IC401 or IC402 data reading error
When data read from IC401 or
IC402 is incorrect.
(1) Reversing valve defective
(2) Heat exchanger thermistor
disconnected
(only in the heating mode)
(Note)
The malfunction mode is entered the
3rd time this abnormal indication
appears (read every 3 minutes).
Electrical parts in the outdoor unit
(1) Indoor interface circuit
(2) Outdoor interface circuit
Please check at the outdoor
electrical led lamp blinking (LD301)
and refer to self diagnosis lighting
mode for outdoor unit.
(1) Room thermistor
(2) Heat exchanger thermistor
(1) Indoor fan locked
(2) Indoor fan motor
(3) Indoor control P.W.B.
IC401 or IC402 abnormal
<Cautions>
(1)
If the interface circuit is faulty when power is supplied, the self-diagnosis display will not be displayed.
(2)
If the indoor unit does not operate at all, check to see if the F-cable is connected or disconnected.
(3)
To check operation again when the timer lamp is blinking, you can use the remote control for operation
(except for mode mark 1).
1
2
3
4
5
6
7
( – – Lights for 0.5 sec. at interval of 0.5 sec..)
– – 10 times
– – – – – – 3 times
– – – – – – – – 1 time
– – – – – – – 2 times
– – 13 times
5 sec.
5 sec.
5 sec.
5 sec.
5 sec.
1
– – 9 times
5 sec.
– – 4 times
5 sec.
Summary of Contents for RAC-50YH4
Page 37: ... 9 MODEL RAS 50YH4 CIRCUIT DIAGRAM ...
Page 38: ...CIRCUIT DIAGRAM MODEL RAC 50YH4 41 ...
Page 40: ... 43 COMPONENT SIDE SOLDERING SIDE MODEL RAS 50YH4 RECEIVING P W B MARKING ON P W B ...
Page 41: ... 44 MODEL RAC 50YH4 MAIN P W B Marking on P W B COMPONENT SIDE ...
Page 90: ... 100 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50YH4 ...
Page 108: ... 2 465 56 0 4 0 114 70 6 1 4 5 50Y ...
Page 110: ... 0 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 50YH4 ...
Page 112: ...HITACHI SM0226 Printed in Malaysia RAS 50YH4 RAC 50YH4 ...