How to run the product with the outdoor unit test switch
1. Turn on the outdoor terminal boards L and N (220-230 V AC).
If the indoor electrical parts is out of order and if you wish to run the outdoor unit
If you release your finger from the test switch within 1 sec to 5 sec after pressing the switch, the forced cooling operation starts.
※
(If you press the test switch for 5
or longer, the self-check diagnosis starts. In this case, turn the power off and start the procedure from 1 again.)
※
(For the initialization of the expansion valve, it may take 1 min until the operation starts.)
after the power turns on), confirm that the "LD301" changes to blinking 9 times (communication error).
2. Confirm that the "LD301" blinks once from the terminal side of the outdoor unit. Afterwards (when about 30 sec elapses
3. When the "LD301" is blinks 9 times, if you press the test switch, the "LD301" lights up.
4. When you press the test switch again for 1 sec or longer, the unit stops the operation.
sec
RAC-25/35/50WXEN
46
Summary of Contents for RAC-25WXEN
Page 2: ... DANGER 2 ...
Page 6: ...SPECIFICATIONS 3 RAC 25 35WXEN SHEATHED HEATER 200W AC 230V RAC 50WXEN 6 ...
Page 13: ...WIRING DIAGRAM MODEL RAC 25 35 50WXEN 13 ...
Page 14: ...MODEL RAC 25 35 50WXEN 14 ...
Page 21: ...L N 300 330 L N 6 5 37 21 2 0 1 5 8 7 23 5 7 21 21 ...
Page 22: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 22 ...
Page 26: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 26 ...
Page 28: ...2A Fuse DC300 330V 7 1 7 28 ...
Page 29: ...2A DC300 330V 30 60 29 ...
Page 39: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25 35 50WXEN 39 ...
Page 52: ...RAC 25WXEN RAC 35WXEN RAC 50WXEN JCH WH NO 0123E 52 ...