3
1
Relay PCB
Fig 8-1
When the outdoor temperature is lower than a certain temperature, the base heater begins to work and the
defrosting ability is enhanced.
When the outdoor temperature is higher than a certain temperature (7±3°C), the protector will work arel.
The power supply of base heater will be cut off.
When the base heater exceeds 119°C, the temp. fuse will act and cut off the power supply.
8. Base Heater Circuit
CN4
FU5(3A Fuse)
AC230V
RL5
Heater relay
VH3P
Base Heater
Temp. Fuse
protector
30
Summary of Contents for RAC-25WXEN
Page 2: ... DANGER 2 ...
Page 6: ...SPECIFICATIONS 3 RAC 25 35WXEN SHEATHED HEATER 200W AC 230V RAC 50WXEN 6 ...
Page 13: ...WIRING DIAGRAM MODEL RAC 25 35 50WXEN 13 ...
Page 14: ...MODEL RAC 25 35 50WXEN 14 ...
Page 21: ...L N 300 330 L N 6 5 37 21 2 0 1 5 8 7 23 5 7 21 21 ...
Page 22: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 22 ...
Page 26: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 26 ...
Page 28: ...2A Fuse DC300 330V 7 1 7 28 ...
Page 29: ...2A DC300 330V 30 60 29 ...
Page 39: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25 35 50WXEN 39 ...
Page 52: ...RAC 25WXEN RAC 35WXEN RAC 50WXEN JCH WH NO 0123E 52 ...