The LD301 blinks 12 times
Fan lock stopped
The LD301 blinks 11 times.
Fan stopped due to a strong wind
It is a pause due to a strong wind. As the wind
weakens, the product will start again.
The product detected an abnormality in the
outdoor fan and stopped its operation. Possible
causes include a pause due to a strong wind,
foreign matter in the fan, abnormality in the fan
motor, and abnormality in the drive circuit.
Check if the fan is clear of foreign
matter and abnormalities.
Remove all foreign matter.
If the fan is abnormal, replace the
fan.
Is the wind too strong?
Check if the product can restart all
right. (It takes several minutes for
it to start again.)
This is not a sign of a failure in the
outdoor fan motor or outdoor electrical
parts.
After restarting,
the product will
run continuously.
It stops
Check the outdoor fan motor. (For details, see
the page on the outdoor fan motor or the
instruction plate on the lid of the electrical
parts.) Is the outdoor fan motor abnormal?
Fan motor
abnormal
Replace the outdoor fan motor.
Fan motor normal
Replace the outdoor electrical
parts (in the case of an
abnormality in the drive circuit of the
outdoor fan).
Check the fan motor for loose
connectors.
Insert the connector.
Yes
Yes
The LD301 blinks 14 times
Change the outdoor ele. unit.
The creepage breaker have already set?
Yes
Q601,Q602
have malfunction
No
No
Abnormal
Does the compressor insulation OK?
Change the compressor and then
check the outdoor ele. unit .
Abnormal
Abnormal
Normal
Normal
Normal
Change the outdoor ele. unit.
Q601,Q602 abnormal
No
Yes
Active voltage abnormal
Stop due to residual
ice
Normal
Abnormal
Please replace the
electric box
of ODU
Please correct the connection of the heater wire or
replace the heater
Clean the
ice
remained in the base, please
check the connection and disconnection of the
heater wire
44
Summary of Contents for RAC-25WXEN
Page 2: ... DANGER 2 ...
Page 6: ...SPECIFICATIONS 3 RAC 25 35WXEN SHEATHED HEATER 200W AC 230V RAC 50WXEN 6 ...
Page 13: ...WIRING DIAGRAM MODEL RAC 25 35 50WXEN 13 ...
Page 14: ...MODEL RAC 25 35 50WXEN 14 ...
Page 21: ...L N 300 330 L N 6 5 37 21 2 0 1 5 8 7 23 5 7 21 21 ...
Page 22: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 22 ...
Page 26: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 26 ...
Page 28: ...2A Fuse DC300 330V 7 1 7 28 ...
Page 29: ...2A DC300 330V 30 60 29 ...
Page 39: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25 35 50WXEN 39 ...
Page 52: ...RAC 25WXEN RAC 35WXEN RAC 50WXEN JCH WH NO 0123E 52 ...