– 28 –
AFTER SALE SERVICE AND WARRANTY
WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS.
When it does not operate
●
Is the fuse all right?
●
Is the voltage extremely high or low?
●
Is the circuit breaker “ON”?
●
Was the air filter cleaned?
●
Does sunlight fall directly on the outdoor unit?
●
Is the air flow of the outdoor unit obstructed?
●
Are the doors or windows opened, or is there any source of
heat in the room?
●
Is the set temperature suitable?
CONDITION
CHECK THE FOLLOWING POINTS
Notes
●
In quiet operation or stopping the operation, the following phenomena
may occassionally occur, but they are not abnormal for the operation.
(1)
Slight flowing noise of refrigerant in the refrigerating cycle.
(2)
Slight rubbing noise from the fan casing which is cooled and then
gradually warmed as operation stops.
●
The odor will possibly be emitted from the room air conditioner because
the various odor, emitted by smoke, foodstuffs, cosmetics and so on,
sticks to it. So the air filter and the evaporator regularly must be cleaned
to reduce the odor.
●
Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above
inspections. Inform your agent of the model of your unit, production number, date of installation. Please also
inform him regarding the fault.
●
Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the
specified capacity.
When it does not cool well
When it does not hot well
Please note:
On switching on the equipment, particularly when the room light is dimmed, a slight brightness fluctuation
may occur. This is of no consequence.
The conditions of the local Power Supply Companies are to be observed.
Minimum
Maximum
Minimum
Maximum
Indoor
Dry bulb
°
C
21
32
20
27
Wet bulb
°
C
15
23
12
19
Outdoor
Dry bulb
°
C
21
43
2
21
Wet bulb
°
C
15
26
1
15
Note
●
Avoid to use the room air conditioner for cooling operation when the outside temperature is below
-10
°
C (14
°
F).
The recommended maximum and minimum operating temperatures of the hot and cold sides
should be as below:
Cooling
Heating
Summary of Contents for RAC-25NH5
Page 31: ... 29 MODEL RAK 25NH5 RAK 35NH5 ...
Page 37: ...CIRCUIT DIAGRAM MODEL RAK 25NH5 RAK 35NH5 37 ...
Page 38: ...CIRCUIT DIAGRAM MODEL RAC 25NH5 RAC 35NH5 39 ...
Page 40: ... 42 MODEL RAK 25NH5 RAK 35NH5 RECEIVING P W B Marking on P W B ...
Page 41: ... 43 MODEL RAC 25NH5 RAC 35NH5 MAIN P W B Marking on P W B COMPONENT SIDE ...
Page 53: ... 64 ...
Page 54: ... 65 ...
Page 55: ... 66 ...
Page 56: ... 67 ...
Page 90: ... 101 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25NH5 RAC 35NH5 ...
Page 92: ... 103 2 Outdoor unit does not operate but receives remote infrared signal ...
Page 94: ... 105 6 Check the main P W B power circuit ...
Page 95: ... 106 CHECKING THE REMOTE CONTROLLER ...
Page 100: ... 111 ...
Page 106: ... 117 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAK 25NH5 RAK 35NH5 ...
Page 112: ...HITACHI PM NO 0324E Printed in Malaysia RAK 25NH5 RAC 25NH5 RAK 35NH5 RAC 35NH5 ...