– 98 –
NO
YES
NO
NO
YES
YES
YES
NG
NG
NO
NO
NO
YES
YES
NO
NO
YES
YES
OK
OK
YES
NO
NO
YES
YES
YES
NO
YES
YES
NO
NO
NO
Is AC 220V voltage being generated
between terminals A and B of the terminal
board?
Is a DC 35V voltage generated between
terminals C and D of the terminal board?
Is AC 220V voltage being generated at
power outlet?
Check power outlet and breaker and
repair defective parts.
Check power cord, power switch and
terminal board. Repair defective parts.
Check the indoor/outdoor connection
cable and correct the abnormal state
(wrong connection, poor insertion, etc.).
Correct the connection.
Check the power circuit and peripherals
and correct the defective parts.
Replace the remote controller.
Replace the light receiving unit.
Replace IC401.
Check that there is no abnormality such
as a pattern short on the P.W.B., heating
of parts, etc. and replace REG1.
(If the output is 15V or more, it is also
abnormal. Replace it.)
Check that there is no abnormality such
as a pattern short on the P.W.B., heating
of parts, etc. and replace REG2.
Check the reset circuit and repair
defective parts.
Replace the micro computer and
oscillator.
Correct the lead wires, connection of the
connector.
Is a AC 220V voltage generated between
terminals A and B of the terminal board
in the outdoor unit?
Is a DC 35V voltage generated between
terminals C and D of the terminal board
in the outdoor unit?
Are jumper cables C and D connected in
reverse?
Check the remote controller. (Refer to
Checking the remote controller .)
Is there poor contact of CN2, disconnec-
tion of leads, etc.?
Is DC 12V voltage being generated at
both ends of C102?
Is a DC 12V voltage generated between
and
G
of REG2?
Is a DC 5V voltage generated between
o and
G
of REG2?
Is the air conditioner operated by pressing
the temporary operation switch?
Does the timer lamp blink 13 times when
the breaker is turned ON?
Is the control voltage generated normally?
Is micro computer reset input (pin
17
) set
to Hi ?
Does micro computer clock (pins
15
,
16
)
oscillate normally?
Replace the control P.W.B..
Perform a final check of operation.
I