– 49 –
Dehumidifying
Cooling preset
Start/Stop Switch
Low humidity
High humidity
15 sec.
5 min. OFF/1 min. ON
6 min. OFF/1 min. ON
32 sec.
32 sec.
30 sec.
Room temperature
judgement
15 sec.
15 sec.
15 sec.
Operation lamp
Humidity judgement
Indoor fan
Outdoor fan
Reversing valve
Hi
Med
Lo
Hi
Med
Lo
3000
SDMAX
SDRPM
Compressor
rotation speed
1 min.
1 min.
1 min.
1 min.
Thermostat judgement
temperature
Room temperature
judgement
Room temperature
30 sec.
(1) 30 seconds after the operation is started, when the room temperature is (cooling preset temperature) – (1.33˚C) or less, the operation is done assuming as the preset
temperature = (room temperature at the time) – (2˚C).
(2) The indoor fan is operated in the "Lo" mode, OFF for 5 minutes and ON for 1 minute (at high humidity) or OFF for 6 minutes and ON for 1 minute (at low humidity),
repeatedly according to the humidity judgement when the thermostat is turned OFF.
(3) When the operation is started by the themostat turning ON, the start of the indoor fan is delayed 32 seconds after the start of compressor operation.
(4) The compressor is operated forcedly for 3 minutes after operation is started.
(5) The miniumu ON time and OFF time of the compressor are 3 minutes.
Note:
Cooling defrost
Thermostat OFF
Refer to the basic operation.
15 sec.
minimum 3 min.
Note: (1) Compressor stop time is 3 minutes minimum.
Compressor rotation
speed
Thermostat
judgement
Indoor fan
Outdoor fan
Hi
Med
Lo
TEIOF
Indoor unit heat exchager temperature
TEION
1 min.
3000
min-
1
Note:
1. Refer to data in page 41 Table 1 for each constant shown by capital letters in the diagram.