– 85 –
Is 230V being generated at
terminals A
and
B?
Are the connections for
terminals C and D correct?
Is 5V being generated between
Pin 4 (0V) and Pin 3 (5V) at CN
Is the 15A
fuse normal?
[No operation or abnormal operation]
Be sure to turn the power of
f
before correcting the connection.
mainly
, varistor (VS2), 3A
fuse,
smoothing capacitors, IPM, etc.
The SW power supply
s overcurrent protection is
activated, disabling the microcomputer
.
Correct properly
.
If the 15A
fuse has blown,
be aware that other parts
may also be defective
Replace defective parts.
Is the power circuit normal?
See the description on power
circuit for details.
Is the switching power
circuit OK?
Has the 3A
fuse blown?
Check to see if C and D cables are
connected correctly
.
If reversed or incompletely inserted,
correct the cable connection.
Replace any defective parts.
If the 3A
fuse has blown, the varistor 2, etc.
may also be defective.
With the piping and lines (A,
B, C, D) connected, operate
the unit in the forced cooling
mode using the outdoor unit
service switch.
How did the self-diagnosis
lamp (LD301) blink?
See the self-diagnosis
lamp mode.
Ye
s
Ye
s
Power is OK
Ye
s
Ye
s
Ye
s
No
No
No
No
NG
(Fuse blown)
CHECKING OUTDOOR UNIT ELECTRICAL PARTS
18 (test pin)?
Summary of Contents for RAC-18YH4
Page 21: ... 19 GRAM 18YH4 RAC 18YH4 CAUTION The marked parts are very important ones for safety ...
Page 23: ... 21 RAS 18YH4 MODEL ...
Page 24: ... 23 RAC 18YH4 MODEL H8 3 0 3 9 AX 8 T 1 0 ...
Page 27: ... 26 MAIN P W B MARKING ON P W B COMPONENT SIDE SOLDERING SIDE MODEL RAC 18YH4 ...
Page 29: ... 29 button MODEL RAS 18YH4 BASIC MODE 31 33 33 33 37 35 ...
Page 35: ... 38 REFRIGERATING CYCLE DIAGRAM MODEL RAS 18YH4 RAC 18YH4 SUCTION TANK SUCTION TANK ...
Page 99: ...Printed in Japan TSK AW NO 0004E RAS 18YH4 RAC 18YH4 ...