– 35 –
1.33˚
C.
SFTDSW
0.66˚
C.
Fan speed set to "auto"
1 min.
Basic Heating Operation
Start
Stop
Stop
Stop
Start
Start
Thermo
OFF
Thermo
OFF
Heating set temperature
(remote control set temperature
(+))
Start/stop button
Thermo judgment
Indoor fan
Ultra-Hi
Hi
Med
Lo
Ultra-Lo
Operation lamp
Max.
Rating
3000
0
Compressor speed
Outdoor fan
Reversing valve (cooling "on" model)
Thermo OFF
Dash period
TWMAX
Wtd
Defrost signal
Preheating judgment
30sec.
30sec.
10sec.
15sec.
15sec.
15sec.
15sec.
15sec.
10sec.
15sec.
15sec.
3min.
Max. 3 min.
Preheating released
Control by
heat exchanger temperature
Control by
heat exchanger temperature
15sec.
Control by
heat exchanger temperature
Control by
heat exchanger temperature
Control by
heat exchanger temperature
18˚C
10sec.
30sec.
30sec.
10sec.
30sec.
30sec.
30sec.
30sec.
30sec.
30sec.
10sec.
Preheat released
WMIN
(WSTD)
(WMAX)
NOTE (10)
WMAX2
Notes:
(1) Condition for entering into Hot Dashed mode. When fan set to “Hi” or “Auto mode” and i) Indoor temperature is lower than 18
°
C, and ii) outdoor temperature is lower than 10
°
C,
and iii) Temperature difference between indoor temperature and set temperature has a corresponding compressor rpm (calculated value in Table 3) larger than WMAX.
(2) Hot Dashed will release when i) Room temperature has achieved the set tempe SFTDSW. ii) Thermo off.
(3) During Hot Dashed operation, thermo off temperature is set temperature (with shift value) +3
°
C. After thermo off, operation continue in Fuzzy control mode.
(4) Compressor minimum “ON” time and “OFF” time is 3 minutes.
(5) During normal heating mode, compressor maximum rpm WMAX will maintain for 120 minutes if indoor temperature is higher than 18
°
C. No time limit constrain if outdoor temperature is
lower than 4
°
C.
(6) During Hotkeep or Defrost mode, indoor operation lamp will blink at interval of 0.5 seconds “ON” and 0.5 second “OFF”.
(7) When heating mode starts, it will enter into Hotkeep mode if indoor heat exchanger temperature is lower than YNEOF + 0.33
°
C.
(8) When fan is set to “Lo”, compressor rpm will be limited to WBEMAX. When fan is set to "Med", compressor rpm will be limited to WJKMAX.
(9) In “Ultra-Lo” fan mode, if indoor temperature is lower than 18
°
C, indoor fan will stop. If indoor temperature is higher than 18
°
C + 0.33
°
C, fan will continue in “Ultra-Lo” mode.
During Hotkeep or Defrost mode, fan will continue in “Ultra-Lo” mode.
(10) During Hot Dashed, when room temperature reaches set tempe SFTDSW compressor rpm is actual rpm x DWNRATEW.
Temperature
Calculated
difference
compressor rpm
1.66
°
C
1900 min
–1
2.00
°
C
2400 min
–1
2.33
°
C
2900 min
–1
2.66
°
C
3400 min
–1
3.00
°
C
3900 min
–1
3.33
°
C
4400 min
–1
3.66
°
C
4900 min
–1
Table 3 Compressor rpm
Notes:
1. See the data in Table 1-Table 2 on
page 47 & 49 for each constant in
capital letters in the diagrams.
(with shift value)
Summary of Contents for RAC-18YH4
Page 21: ... 19 GRAM 18YH4 RAC 18YH4 CAUTION The marked parts are very important ones for safety ...
Page 23: ... 21 RAS 18YH4 MODEL ...
Page 24: ... 23 RAC 18YH4 MODEL H8 3 0 3 9 AX 8 T 1 0 ...
Page 27: ... 26 MAIN P W B MARKING ON P W B COMPONENT SIDE SOLDERING SIDE MODEL RAC 18YH4 ...
Page 29: ... 29 button MODEL RAS 18YH4 BASIC MODE 31 33 33 33 37 35 ...
Page 35: ... 38 REFRIGERATING CYCLE DIAGRAM MODEL RAS 18YH4 RAC 18YH4 SUCTION TANK SUCTION TANK ...
Page 99: ...Printed in Japan TSK AW NO 0004E RAS 18YH4 RAC 18YH4 ...