– 22 –
Ƶ
How to select Mode
A
or Mode B of WEEKL
Y
TIMER setting.
1.
Press
(WEEKL
Y) button.
and
blink on the display
.
(Normally Mode
A
will blink
first).
2.
Press
(WEEKL
Y) button again.
and
blink on the display
.
3.
Select Mode
A
or Mode B. Press
(SEND) button while directing the
remote controller towards the indoor unit for about 3 seconds.
T
imer lamp
on the indoor unit will blink rapidly
.
After beep sound emitted from indoor unit,
TIMER lamp will light up.
Please ensure that the TIMER lamp lights up.
This indicates that Mode
A
or Mode B selection and active W
EEKLY
T
IMER
have been confirmed.
Ƶ
Setting non-active WEEKL
Y
TIMER .
1.
Direct the remote controller towards the indoor unit and press
(CANCEL) button.
Beep sound will be emitted from indoor unit and
TIMER lamp will be OFF
.
Reservation indication on remote display will also disappear
.
This indicates that non-active WEEKL
Y
TIMER has been confirmed.
ƽ
T
o
activate back the setting of WEEKL
Y
TIMER , repeat the steps for
"How to select Mode
A
or Mode B of WEEKL
Y
TIMER setting".
NOTE
ƽ
When setting ONCE
TIMER, operation of WEEKL
Y
TIMER is interrupted.
After ONCE
TIMER operation
is complete, WEEKL
Y
TIMER operation will be activated.
ƽ
When ONCE
TIMER is cancelled, operation of WEEKL
Y
TIMER is also cancelled. Need to set WEEKL
Y
TIMER operation for activation.
ƽ
After auto restart, WEEKL
Y
TIMER operation is cancelled. Need to set WEEKL
Y
TIMER operation for
activation.
1
2
1
WEEKL
Y TIMER OPERA
TION
Step 2: Select Mode
A
or Mode B and activate or deactivate WEEKL
Y
TIMER.
3
– 21 –
ENGLISH
5.
Press
(ON-OFF
TIMER) button to select ON
TIMER or OFF
TIMER
reservation.
6.
Press
(TIME) button to set time reservation.
7.
Press (TEMP
or
) button to set temperature reservation.
8.
Press
(OK) button.
The reservations are set. Day
, program
number
, ON reservation, setting temperature will light up.
will be
continuously blinks. If reservation is not complete, settings will not be
stored in memory
.
T
o
continue with the reservation, press
buttons.
Follow step 3 to 8 for reservation.
9.
After all the reservations have been set, press
(SEND) button while
directing the remote controller towards the indoor unit for about 3 second
s
T
imer lamp on the indoor unit will blink rapidly
.
After beep sound emitted from indoor unit,
TIMER lamp will light up.
Please ensure that the TIMER lamp lights up.
This indicates that the reservation has been stored in the indoor unit and
T
imer function has been completed.
The reservation contents will appear on the remote controller display
.
If
TIMER lamp on the indoor unit does not light up, press
(SEND) button while directing the remote controller towards the indoor
unit for about 3 seconds.
CAUTION
!
Do not press
(CANCEL) button during reservation
setting because this will result in all reservation contents to be lost.
The reservation contents will not stored in the indoor unit until
(SEND) button has been pressed.
5
6
7
8
9
NOTE
ƽ
Up to 6 programs can be set per day
. Setting ON
TIMER or OFF
TIMER for each program number can
number will automatically arranged so that program number 1 shall have the earliest time and program
number 6 shall have the latest time.
If the setting time is the same, Priority will be given to the latest reservation contents.
after reservations have been made , all current reservations will be lost.
WEEKL
Y TIMER OPERA
TION
ƽ
ƽ
ƽ
be at random. When pressing
(SEND) button, the set ON TIMER or OFF TIMER for each program
ƽ
CAUTION
!
If the remote controller is left idle and
(SEND) button is not pressed within 3 minutes
Summary of Contents for RAC-18WSPA
Page 2: ... DANGER ...
Page 32: ...WIRING DIAGRAM OF THE PRINTED WIRING BOARD Remote controller RAR 5E2 ...
Page 33: ...CIRCUIT DIAGRAM MODEL RAK 18 25 35PSPA ...
Page 34: ...MODEL RAC 18 25 35WSPA ...
Page 39: ... ...
Page 41: ... ...
Page 44: ... ...
Page 54: ...10 10 10 10 R921 R924 R642 R544 R542 R610 R922 DSW1 DSW1 R923 R541 R543 93 ...
Page 55: ...TERMINAL BOARD RAC 18 25 35WSPA ...
Page 56: ... ...
Page 57: ... 䌔䌅䌓䌔䇭䌓䌗䌉䌔䌃䌈 䌓䌗 䌓䌅䌌䌆䇭 䌃䌈䌅䌃䌋 䌌 䋨 䌁䋩䌎 䋨 䌂䋩䇭 䇭 䌃䇭 䇭 䌄 ...
Page 59: ... ...
Page 60: ...5 Electric expansion valve circuit 22 23 24 25 12 13 14 15 5 4 3 2 34 32 30 29 RED ...
Page 61: ...3 15A Fuse Switching power source ...
Page 62: ...3 15A 3 15A DC260 360V ...
Page 70: ......
Page 72: ... ...
Page 75: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 18 25 35WSPA ...
Page 76: ...77 ...
Page 77: ... ...
Page 79: ...AK 18 25 35PSPA RAC 18 25 35WSPA R L E D O M ...
Page 82: ... ...
Page 85: ...MODEL RAC 18 25 35WSPA ...
Page 87: ...9 V 3 V 3 Q L D 0 3 U R R G W X R H F D O S H 5 V 3 9 ...
Page 90: ... 1 7 5 027 21752 5 ...
Page 91: ...37 ...
Page 92: ...Please set the DIP switch No 6 to ON accordingly Refe to page r 54 ...
Page 93: ...54 ...
Page 94: ... ...
Page 96: ...㶎 㶎 Do not operate for 5 minutes or more Model RAC 18 25 35WSPA ...
Page 97: ...PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAK 18PSPA RAK 25PSPA RAK 35PSPA ...
Page 99: ...MODEL RAC 18 25 35WSPA 45 46 48 50 51 52 53 ...
Page 101: ... 7 RAK 18PSPA RAC 18WSPA RAK 25PSPA RAC 25WSPA HHAW NO 0073E RAK 35PSPA RAC 35WSPA ...