– 42 –
MAINTENANCE (continued)
Maintenance of electric dust collector electrodes and ionized mist generator
1
Stop the operation with the remote controller
and unplug the power plug (or turn off the
circuit breaker).
2
Open the front panel.
(Refer to page 8 on opening the front panel)
CAUTION
3
Slowly open the vertical air deflectors using
both hands.
Horizontal air
deflectors
•
Be sure to open slowly using both hands as shown in the illustration.
Otherwise, it may cause malfunction.
•
Do not use excessive force to move the air deflector beyond the stopper located below it.
Otherwise, it may cause malfunction.
4
Remove the dirt on the electric dust collector electrodes (2 places) and ionized
mist generator with a toothbrush.
•
Be sure to use a dry toothbrush.
•
Lightly brushed off the dust.
Electric dust collector
electrodes
Ionized mist generator
5
Close the front panel.
(Refer to page 9 on closing the front panel)
6
Plug in the power plug (or turn on the circuit breaker).
Electric dust collector
electrodes
CAUTION
•
Do not touch the electric dust collector electrodes and ionized mist generator while the air conditioner
is in operation
High voltage generated at these parts could result in electrical shock.
•
Do not splash or direct water to the electric dust collector electrodes and ionized mist generator
It may cause short circuit or malfunction.