– 6 –
DEHUMIDIFYING OPERATION
Use the device for dehumidifying when the room temperature is over 16°C.
When it is under 15°C, the dehumidifying function will not work.
■
Dehumidifying Function
When the room temperature is higher than the temperature setting: The device will dehumidify the
room and reducing the room temperature to the preset level.
When the room temperature is lower than the temperature setting: Dehumidifying will be performed at
the temperature setting slightly lower than the current room temperature, regardless of the temperature
setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature
becomes lower than the setting temperature.
■
As the settings are stored in memory in the remote controller, you
only have to press the (DEHUMIDIFY) button next time.
Set the desired room temperature with the TEMPERATURE
button (the display indicates the setting).
The range of 20 ~ 26˚C is recommended as
the room temperature for dehumidifying.
Press the
button so that the display indicates
(DEHUMIDIFY).
Dehumidifying operation starts with a beep.
The FAN SPEED is set at LOW automatically.
The FAN SPEED button does not work.
Press the (STOP) button to stop operation.
STOP
I Manual RAS-18G5_3 languages.indb 6
3/3/2011 10:28:24 AM
Summary of Contents for RAC-18G5
Page 22: ...ENGLISH 19 MEMO ...
Page 23: ... 20 MEMO ...
Page 45: ...DEUTSCH 19 NOTIZEN ...
Page 46: ... 20 NOTIZEN ...
Page 68: ...FRANÇAIS 19 MÉMO ...
Page 69: ... 20 MÉMO ...