
– 6 –
MODEL RAS-10G5 / RAC-10G5
Figure showing the installation of Indoor and Outdoor unit
In case the pipe length is more than 8m, add refrigerant R410A at 15 gram per every meter exceeds. However, pipe
length shall not exceed 15m.
CAUTION
!
●
The difference in height
between the indoor and
outdoor unit should be kept
max 5m.
●
The connecting pipe, no
matter big or small, should
all be insulated with insulation
pipe and then wrapped with
vinyl tape. (The insulator will
deteriorate if it is not wrapped
with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commercial products).
Be sure to
completely
seal any gap.
Summary of Contents for RAC-10G5
Page 31: ... 30 MODEL RAC 10G5 RAC 14G5 ...
Page 35: ... 34 WIRING DIAGRAM MODEL RAS 10G5A1 ...
Page 36: ... 35 WIRING DIAGRAM MODEL RAS 14G5AC 63CHA1 ...
Page 37: ... 37 CIRCUIT DIAGRAM Remote Control ...
Page 38: ...PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 39 ...
Page 39: ... 41 BLOCK DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 ...
Page 42: ... 46 REFRIGERANT CYCLE DIAGRAM MODEL RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...
Page 50: ... 54 ...
Page 56: ... 60 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 10G5 14G5 ...
Page 59: ... 63 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 10G5 14G5 ...
Page 62: ...HITACHI PM NO 0487E Printed in Malaysia RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...