Operation mode
Control function
Cooling
Sensor dehumidi
cation
1
Start/stop button,
basic mode
2
Timer
operation
ON timer
OFF timer
Automatic
MED
LO
HI
●
Same as on the left.
●
Same as on the left.
●
Same as on the left.
3
Circulation
mode
Thermostat operation
H
A
HI
L
A
MED
S
A
LO
●
The power relay is
delayed by 2 seconds
from the start of
thermostat operation.
●
“HI”, “MED”, or “LO” operation is
executed according to the thermostat
signal. (Refer to “Thermostat operation”.)
●
“LO” and “Stop” are repeated according to the thermostat signal, independent of the setting.
Notes:
●
Forced operation by start/stop button ON is executed even with thermostat OFF.
●
The room temperature 30 sec after operation start, minus 0.66 deg, becomes the se temperature.
●
When the room temperature is 16°C or lower, 16°C becomes the set temperature.
●
The other operations are the same as for (1).
(2) Set temperature is higher than room temperature.
(1) When the set temperature is lower than the room temperature.
4
BASIC MODE
MODEL RAS-10G5/14G5 // RAC-10G5/14G5
●
The min. ON time of the power relay is 3 minutes, and the min. OFF time also is 3 minutes.
●
The indoor fan is not delayed with operation start by start/stop button ON.
●
The indoor fan is delayed by 5 sec with operation start by thermostat operation.
No.
5
– 43 –
Control function
Operation mode
Cooling
Sensor dehumidi
cation
Notes:
●
60 minutes after the sleep key is switched on, sleep operation is started.
●
When the sleep key is switched on during OFF timer operation, the OFF timer will be canceled.
No.
●
The set temperature
after sleep shift in sensor
dehumidi
cation operation
is limited by 16°C.
Yes
Yes
Yes (automatic)
Yes
Yes
Yes
Yes
Yes
Cooling
Item
Operation switching
Temporary switch
Service switch
Nice temperature reservation
Sleep circuit
Auto swing direction
Filter sign
Wireless mode
Item
Thermostat
ON temperature
Cooling, Sensor
16
17.3
operation
(Thermostat relay) dehumidi
cation
24
25.3
power relay (°C)
32
33.3
Differential (°C)
0.33
Table 1 Speci
cations
Table 2 Sensor operation values
Other detailed speci
cations
1.
When the room temperature rises within
3 minutes after thermostat OFF during
cooling operation with automatic velocity,
the blowing velocity changes in the order
of S
A
L
A
H in the same way as at
the time of thermostat ON.
2.
In case of switching from “Sensor
dehumidi
cation” operation to “Cooling”,
as it is when the thermostat is ON. 3 min
delay will not be entered. However, the set
room temperature and the blowing velocity
will be according to the remote control
signal.
The same applies for switching from
“Cooling” to “Sensor dehumidi
cation”.
3.
The
lter sign lights after operation of the
indoor fan for 200 hours. The time is cleared
when the “ (AUTO SWING)” button
is pressed while the device is on “STANDBY
MODE”.
4.
When operation by nice temperature
reservation is executed during sleep
operation, normal operation will be
continued, and the advance time becomes
the temperature difference between the set
temperature without sleep shift and the
room temperature.
RAS-10G5/14G5
Sensor
dehumidi
cation
Cooling
Cooling
Summary of Contents for RAC-10G5
Page 31: ... 30 MODEL RAC 10G5 RAC 14G5 ...
Page 35: ... 34 WIRING DIAGRAM MODEL RAS 10G5A1 ...
Page 36: ... 35 WIRING DIAGRAM MODEL RAS 14G5AC 63CHA1 ...
Page 37: ... 37 CIRCUIT DIAGRAM Remote Control ...
Page 38: ...PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 39 ...
Page 39: ... 41 BLOCK DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 ...
Page 42: ... 46 REFRIGERANT CYCLE DIAGRAM MODEL RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...
Page 50: ... 54 ...
Page 56: ... 60 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 10G5 14G5 ...
Page 59: ... 63 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 10G5 14G5 ...
Page 62: ...HITACHI PM NO 0487E Printed in Malaysia RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...