
– 50 –
6. Service Operation Circuit
●
Use the service switch to select “Cooling” temporarily when the interior electric equipment has troubled.
●
Setting the switch to “Cooling” causes continuous cooling room temperature control. To control the room
temperature, turn on and off the disconnect switch. To protect the compressor, wait at least 3 minutes
before turning on again.
●
The fan speed is “MED”.
●
Does not operate is 12V is not generated in the control circuit.
●
When the service switch is used for operation, each change switch is overridden.
●
Setting the service switch to “Cooling” turns on the “Power relay”.
5. Receive circuit
Infrared signals from the wireless remote controller are received by the light receiving unit and output after
being amplifi ed and shaped.
Summary of Contents for RAC-10G5
Page 31: ... 30 MODEL RAC 10G5 RAC 14G5 ...
Page 35: ... 34 WIRING DIAGRAM MODEL RAS 10G5A1 ...
Page 36: ... 35 WIRING DIAGRAM MODEL RAS 14G5AC 63CHA1 ...
Page 37: ... 37 CIRCUIT DIAGRAM Remote Control ...
Page 38: ...PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 39 ...
Page 39: ... 41 BLOCK DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 ...
Page 42: ... 46 REFRIGERANT CYCLE DIAGRAM MODEL RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...
Page 50: ... 54 ...
Page 56: ... 60 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 10G5 14G5 ...
Page 59: ... 63 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 10G5 14G5 ...
Page 62: ...HITACHI PM NO 0487E Printed in Malaysia RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...