– 4 –
There are 3 directions allowed,
namely, horizontally perpen-
dicular to the unit, vertically
down from right, horizontally
out from right.
Don’t form the piping
downward at the left of the unit.
Horizontally
perpendicular
to the unit
Connection
20
Dimension of Mounting Stand
of the outdoor unit
(unit : mm)
35
12
225
8
35
500
100
above 100mm
above 50mm
above 100mm
2,300mm or more
abo
v
e
300mm
m
ust not bend
about 0.45m
Maxim
um pipe length 10m
Minim
um pipe length 5m
*
above 50mm
*
give clearance
as wide as possible
above 200mm
*
above 200mm
above 100mm
above 50mm when
installed on the
ceiling of balcony
above 200mm
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the
insulator is insufficient, please
use commercial products).
The difference in height
between the indoor and
outdoor unit should be kept
below 5m.
The connecting pipe, no
matter big or small, should all
be insulated with insulation
pipe and then wrapped with
vinyl tape. (The insulator will
deteriorate if it is not wrapped
with tape).
The connection of insulated
drain hose.
inner diameter ø 16mm
Please use insulated drain
hose for the indoor piping
(commercial product.)
•
•
mounting stand
Plug
Be sure to
completely
seal any gap
with putty.
The Length of Indoor Unit
Connecting Cord
about
0.9m
about 1.6m
Do not alter the power cord.
Cut away shaded
portion, and finish
the edge of the
opening so that
there is no burr.
Figure showing the Installation
of Indoor and Outdoor unit.