12
English
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
2
).
Connect the air hose.
Do not load any nails in the Nailer.
Set the switching device to the leftward position
(SINGLE SEQUENTIAL ACTUATION MECHANISM).
(Set the switching device to the leftward position
completely as shown in the diagram. Otherwise, it will
not operate properly.)
Leftward position
Switching device
□
THE NAILER MUST NOT LEAK AIR.
(3) Remove the
fi
nger from the trigger and press the
push lever against the wood.
□
THE NAILER MUST NOT OPERATE.
Do not pull Trigger
Depress Push Lever
(4) Separate the push lever from the wood.
Next, point the nailer downward, pull the trigger and
then wait in that position for 5 seconds or longer.
□
THE NAILER MUST NOT OPERATE.
Pull Trigger
(5)
1
Without touching the trigger, depress the push
lever against the workpiece.
Pull the trigger.
□
THE NAILER MUST OPERATE.
2
Hold the trigger back while separating the push
lever from the wood.
□
The nailer will remain in operated status (the
driver blade will remain at the bottom).
3
Remove the
fi
nger from the trigger.
□
Nailer operation will end (the driver blade will
return to the top).
(6) Set the switching device to the rightward position
(CONTACT ACTUATION MECHANISM).
(Set the switching device to the rightward position
completely as shown in the diagram. Otherwise, it will
not operate properly.)
Rightward position
Switching device
With the Nailer o
ff
the workpiece, pull the trigger.
Depress the push lever against the workpiece.
□
THE NAILER MUST OPERATE.
(7) If no abnormal operation is observed, you may load
nails in the Nailer.
Drive nails into the workpiece that is the same type to
be used in the actual application.
□
THE NAILER MUST OPERATE PROPERLY.
ADJUSTING AIR PRESSURE
WARNING
●
Do not exceed
120 psi (8.3 bar
8.5 kgf/cm
2
).
000Book̲NV83A3̲US.indb 12
000Book̲NV83A3̲US.indb 12
2011/07/24 10:31:14
2011/07/24 10:31:14
Summary of Contents for NV 83A3