-16-
Insert the stem of the fuel cell into the hole on the adapter.
To attach the metering valve to a fuel cell:
Fig. 13
(1) Separate the metering
valve and cap from the
gas cartridge.
(2) Press the front side of
the metering valve
forward (stem side)
and downward.
(3) Press the rear of the
metering valve
downward until it seals.
Fig. 14
<Checking the fuel cell>
Problem
Possible cause
Inspection method
Corrective action
Fuel is not
sprayed.
• Fuel is leaking.
• There is no fuel.
• The metering valve
is not set properly.
• Press the stem five
or more times with
the fuel cell held
upright to check
whether fuel is
being sprayed.
• Set the metering valve
properly (and rotate the
valve to secure it in
place).
• Replace the metering
valve with a new one.
• Replace the fuel cell with a
new one.
• The bag in the fuel cell is
damaged.
• Fuel is not sprayed
when the fuel cell
is held upright, but
is sprayed when
the fuel cell is held
horizontally.
• Replace the fuel cell with a
new one.
• Insufficient sealing of the cup
and stem in the metering
valve.
• Check whether fuel
is leaking by
holding down the
stem.
• Replace the metering
valve with a new one.
• The nailer is left under a high
temperature condition.
The nailer is left in direct
sunlight or nails are driven
continuously. <Excessively
high concentration of gas>
• The main body is
hot due to
combustion heat.
• Allow the main body and
fuel cell to cool down.
• Replace the fuel cell with a
new one.
Fuel is
sprayed but
no
combustion
occurs.
• The nailer is left under a low
temperature condition.
0°C or lower temperature
<Low concentration of gas>
• The sprayed fuel is
in a liquid state.
• Warm up the fuel cell.
Instruct the customers on
such necessary measures
as putting the fuel cell in a
pocket or wrapping it in a
thermal insulating
material.
Fuel is sprayed
but no
combustion
occurs.
• The oxygen content of air is low
at such places as highlands at
an altitude of 1,500 meters or
more.
<Excessively high concentration
of gas>
• A large amount of
fuel is sprayed.
• Use the nailer where the
altitude is less than 1,500
meters.
Adapter
[20]
Stem