-19-
<Continued>
Problem
Possible cause
Inspection method
Corrective action
No combustion
occurs.
<Electric section>
Continued
• No spark occurs. (Check
for sparking according to
9-3, “Checking for
Sparking and Corrective
Action.")
• The Battery
[58]
is not
set properly.
• The Battery
[58]
is faulty.
• The battery indicator light
goes on in red.
• Connection failure
between Internal Wire (A)
[60A]
and the Controller
[95].
• The spark plug cable is
disconnected from Spark
Plug (A)
[5]
.
• Faulty insulation of the
spark plug cable wire
• Break in Internal Wire (A)
[60A].
• The spark switch is faulty.
• Spark Plug (A)
[5]
is
stained.
• The wire near the Trigger
[71]
is pinched.
• The Pushing Lever Arm
[77]
is deformed.
• Set the Battery
[58]
properly.
• Replace the Battery
[58]
.
• Charge the Battery
[58]
.
• Connect properly (Fig. 15).
• Connect properly (Fig. 16).
• Replace the Controller
[95]
.
• Replace Internal Wire (A)
[60A]
.
• Replace Internal Wire (A)
[60A]
.
• Clean Spark Plug (A)
[5]
(Fig. 17).
• Position the wire correctly
(Fig. 15).
• Replace the Pushing
Lever Arm
[77]
.
No nail is driven
though nails are
set properly and
combustion is
normal.
<Combustion section>
• The Piston
[27]
does not
return completely.
• Check the position of the
Piston
[27]
.
• Piston Ring (B)
[17]
is
worn.
• The Reed Valve
[50]
is
deformed.
• The cylinder is stained
inside.
• Piston Ring (A)
[26]
is
damaged.
• Return the Piston
[27]
to
the uppermost position
with a flat-blade
screwdriver.
• Hold down Pushing Lever
(A)
[82]
securely until
nailing operation is
completed.
• Replace Piston Ring (B)
[17]
.
• Replace the Reed Valve
[50]
.
• Clean inside the cylinder.
• Replace Piston Ring (A)
[26]
.
Output is low.
• Discharge and cooling
are insufficient.
• The outside air
temperature and altitude
exceed specifications.
• The Filter Mesh
[2]
is
clogged.
• Check the outside air
temperature and altitude.
• Clean the Filter Mesh
[2]
(Fig. 12).
• Outside air temperature
range: 0°C to 40°C
• Altitude: Less than 1,500 m
(5,000 feet)
The nailer is
overheated.
• Discharge and cooling
are insufficient.
• The operating speed is
too fast.
• The Filter Mesh
[2]
is
clogged.
• Clean the Filter Mesh
[2]
(Fig. 12).
• Do not use the nailer at
high speed.
Speed: 1 nail/sec.
Continuous operation:
1,000 nails/h
Abnormal noise
is heard during
fan rotation.
*
A rubbing noise may
be heard in some
rare cases, but there
is no problem in
operation.
• Discharge and cooling
are insufficient.
• Check that the Motor
Ass'y
[25B]
, Fan
[11]
and
Nut M3
[8]
are mounted
properly.
• Mount each part properly.