(b) Reassembly
Fit Gasket (A)
[23]
in the groove of the Chamber Head
[22]
and mount it to the Chamber
[24]
. Do not
protrude Gasket (A)
[23]
from the groove. Be careful of the mounting direction of Gasket (A)
[23]
(Fig. 48).
* After mounting the Cylinder Ass'y
[42]
to the Housing
[71],
mount the Switch Plate
[34]
to the Chamber
[24]
.
Note that the Cylinder Ass'y
[42]
cannot be mounted to the Housing
[71]
if the Switch Plate
[34]
is mounted
to the Chamber
[24]
first.
Fig. 48
Convex portion of
Gasket (A)
[23]
Gasket (A)
[23]
Chamber Head
[22]