Chapter 13 – The optional remote operators
13-2
The monitor mode
The following table describes the display contents. The
*
)
marked column indicates whether parameters can
be changed during inverter operation (Y) or not (N).
Function Display
contents
Standard
setting
Parameter
range
*
)
Notes
Refer
to
Frequency set value
Set value via O/OI
Set value via pot(NA)
Jogging mode
Multistage freq. 1
...
Multistage freq. 15
FS000.0 0.0Hz
TM000.0 0.0Hz
VR000.0 0.0Hz
JG000.0 0.0Hz
1S000.0 0.0Hz
...
15S000.0 0.0Hz
0.0Hz 0.0~360.0Hz
Y
Set value is displayed on the
left, actual value on the right.
In the centre an
F
indicates
forward run and an
R
indicates
reverse run.
FS
: Now the set value can
be entered.
TMP
,
FSP
,
VRP
,
1P~15P
:
PID control active
d 01
F 01
1. Acceleration time
ACC1 0010.0S
F 02
1. Deceleration time
DEC1 0010.0S
10.0s
(15.0s)
0.1~3000.0s Y
F 03
Frequency
source
F-SET-SELECT TRM
TRM
VR, TRM,
REM
N
A 01
Run command source
F/R-SELECT TRM
TRM TRM,
REM
N
VR: NOT IN USE!
TRM: Input O/OI
REM: Remote operator
A 02
Scaled output
frequency
/Hz01.0 01.0
1.0 0.1~99.9
Y
Display
only
d 07
b 86
Motor current
Im 0.0A
0.0%
Display only
-
Displays current in A (
left
)
and % of rated current (
right
)
d 02
Magnetizing current
I
0 A
Rated cur-
rent
* 0.58
0~32A N
b 32
Manual boost
V-Boost Code<11>
11 00~99
Y
A 42
Manual boost fre-
quency adjustment
V-Boost F
10.0%
10% 0.0~50%
Y
A 43
Boost method
V-Boost Mode
0
0 0.
1
N
A 41
Output voltage gain
V-Gain 100%
100 50~100%
Y
A 45
Jogging frequency
Jogging 1.00Hz
1.0Hz 0.5~9.99Hz
Y
A 38
Jogging stop mode
Jog Mode
0
0 0~2
N
A 39
Analog meter adjustm.
ADJ 80
80 0~255
Y
b 81
Remote OPE-J display
contents
PANEL d01
d 01
01~07
Y
b 89
Status of input and
output terminals
TERM LLL
LLLLL
Display only
-
d 05
d 06
ERR1 #
No last trip message available
ERR1 OVER.V
Displays type of trip
(e.g. overvoltage)
ERR1 31.0Hz
Frequency at time of trip
ERR1 12.5A
Current at time of trip
ERR1 787.0Vdc
Voltage between P and N
at time of trip
ERR1 RUN 000001H
Hours of operation at time of trip
ERR2 #
Trip history register:
ERR1
:
Last trip
ERR2
:
Last trip but one
ERR3
:
Last trip but two
ERR3 #
Display only
-
Last trip but one / last
trip but two not available
(For other displays
refer to
ERR1
)
d 08
Trip counter
ERROR COUNT
25
Display only
-
Number of trips so far
-